Literature DB >> 14990847

Steady-state free precession MR imaging: improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion.

Michael Markl1, Scott B Reeder, Frandics P Chan, Marcus T Alley, Robert J Herfkens, Norbert J Pelc.   

Abstract

Tagging with balanced steady-state free-precession (SSFP) magnetic resonance (MR) imaging by using a steady-state storage scheme for myocardial motion analysis was evaluated. Signal-to-noise ratio (SNR), blood-tissue contrast, and tag persistence in volunteers and phantoms showed improved performance of SSFP imaging with tagging compared with that of radiofrequency spoiled gradient-echo (SPGR) MR imaging with tagging. Choice of flip angle with SSFP imaging involved a trade-off among SNR, blood-tissue contrast, and tag persistence. Increased SNR and tag persistence can be achieved simultaneously with SSFP imaging compared with SPGR tagging methods. As a result, the proposed technique may be useful for analysis of diastolic ventricular function. Copyright RSNA, 2004

Mesh:

Year:  2004        PMID: 14990847     DOI: 10.1148/radiol.2303030181

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  [Myocardial MR tagging: analysis of regional and global myocardial function].

Authors:  U Kramer; A Hennemuth; M Fenchel
Journal:  Radiologe       Date:  2010-06       Impact factor: 0.635

2.  Comparison of cardiac MRI tissue tracking and myocardial tagging for assessment of regional ventricular strain.

Authors:  David M Harrild; Yuchi Han; Tal Geva; Jing Zhou; Edward Marcus; Andrew J Powell
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-04       Impact factor: 2.357

3.  Assessment of reverse remodeling predicted by myocardial deformation on tissue tracking in patients with severe aortic stenosis: a cardiovascular magnetic resonance imaging study.

Authors:  Ji-Won Hwang; Sung Mok Kim; Sung-Ji Park; Eun Jeong Cho; Eun Kyoung Kim; Sung-A Chang; Sang-Chol Lee; Yeon Hyeon Choe; Seung Woo Park
Journal:  J Cardiovasc Magn Reson       Date:  2017-10-23       Impact factor: 5.364

4.  Automated assessments of circumferential strain from cine CMR correlate with LVEF declines in cancer patients early after receipt of cardio-toxic chemotherapy.

Authors:  Marie-Pierre Jolly; Jennifer H Jordan; Giselle C Meléndez; Gary R McNeal; Ralph B D'Agostino; W Gregory Hundley
Journal:  J Cardiovasc Magn Reson       Date:  2017-08-02       Impact factor: 5.364

5.  Cardiac Magnetic Resonance Feature Tracking in Aortic Stenosis: Exploration of Strain Parameters and Prognostic Value in Asymptomatic Patients with Preserved Ejection Fraction.

Authors:  Moon Young Kim; Eun Ah Park; Whal Lee; Seung Pyo Lee
Journal:  Korean J Radiol       Date:  2020-03       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.