Literature DB >> 14990821

High-spatial-resolution 3D balanced turbo field-echo technique for MR angiography of the renal arteries: initial experience.

Kenneth L Coenegrachts1, Romhild M Hoogeveen, Johan A Vaninbroukx, Hilde T Bosmans, Didier J Bielen, Geert Maleux, Frederik Maes, Pascal Hamaekers, Raymond H Oyen, Guy J Marchal.   

Abstract

PURPOSE: To compare a multislab balanced turbo field-echo magnetic resonance (MR) angiographic technique, without the use of a contrast agent, with digital subtraction angiography (DSA) for imaging of the renal arteries.
MATERIALS AND METHODS: Twenty-five randomly selected patients (eight women and 17 men; age range, 27-88 years; mean age, 72 years) suspected of having renal artery stenosis underwent both DSA and balanced turbo field-echo MR angiography. A consensus result was obtained among three radiologists in evaluation of main renal arteries on balanced turbo field-echo images and DSA images. Sensitivity, specificity, and negative and positive predictive values of the balanced turbo field-echo technique were calculated, and receiver operating characteristic analysis was performed for depiction of hemodynamically significant stenosis. Cohen kappa analysis was used to assess agreement between the two imaging methods in grading of stenoses and depiction of significant stenosis. Accessory renal arteries also were evaluated.
RESULTS: Fifty main renal arteries and 11 accessory arteries were fully depicted with DSA. DSA depicted 11 stenotic lesions in the main renal arteries. In comparison, balanced turbo field-echo MR angiography enabled visualization of 46 of 50 main renal arteries to their first branching points and depicted 10 of 11 accessory arteries. Sensitivity, specificity, negative predictive value, and positive predictive value of this technique for depiction of significant stenosis were 100% (four of four), 98% (41 of 42), 100% (41 of 41), and 80% (four of five), respectively. The area under the receiver operating characteristic curve was 0.988. kappa was 0.782 for grading of stenoses and 0.877 for depiction of significant stenosis.
CONCLUSION: Multislab balanced turbo field-echo imaging has potential as an MR angiography technique for depiction of normal and diseased renal arteries. Copyright RSNA, 2004

Entities:  

Mesh:

Year:  2004        PMID: 14990821     DOI: 10.1148/radiol.2311030044

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Evaluation of meglumine gadoterate-enhanced MR angiography (MRA) compared with time-of-flight MRA in the diagnosis of clinically significant non-coronary arterial disease: a pooled analysis of data from two clinical trials.

Authors:  D J Shah; T-H Lim
Journal:  Br J Radiol       Date:  2011-12-13       Impact factor: 3.039

2.  Preoperative evaluation of the cystic duct for laparoscopic cholecystectomy: comparison of navigator-gated prospective acquisition correction- and conventional respiratory-triggered techniques at free-breathing 3D MR cholangiopancreatography.

Authors:  Ryo Itatani; Tomohiro Namimoto; Hiroo Kajihara; Akira Yoshimura; Kazuhiro Katahira; Jiro Nasu; Ikuo Matsushita; Fumi Sakamoto; Masafumi Kidoh; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-02-27       Impact factor: 5.315

3.  Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains.

Authors:  Dan Zhu; Wenbo Li; Dapeng Liu; Guanshu Liu; Yigang Pei; Taehoon Shin; Farzad Sedaghat; Qin Qin
Journal:  Magn Reson Med       Date:  2020-02-04       Impact factor: 4.668

4.  Non-enhanced ECG-gated respiratory-triggered 3-D steady-state free-precession MR angiography with slab-selective inversion: initial experience in visualisation of renal arteries in free-breathing children without renal artery abnormality.

Authors:  Dirk Klee; Rotem Shlomo Lanzman; Dirk Blondin; Peter Schmitt; Jun Oh; Burak Salgin; Ertan Mayatepek; Gerald Antoch; Jörg Schaper
Journal:  Pediatr Radiol       Date:  2012-03-31

5.  Inversion-recovery-prepared dixon bSSFP: initial clinical experience with a novel pulse sequence for renal MRA within a breathhold.

Authors:  Pauline W Worters; Manojkumar Saranathan; Alan Xu; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2011-11-16       Impact factor: 4.813

6.  Quadruple inversion-recovery b-SSFP MRA of the abdomen: initial clinical validation.

Authors:  Iliyana P Atanasova; Ruth P Lim; Hersh Chandarana; Pippa Storey; Mary T Bruno; Daniel Kim; Vivian S Lee
Journal:  Eur J Radiol       Date:  2014-06-02       Impact factor: 3.528

7.  Renal artery stenosis: comparative evaluation of gadolinium-enhanced MRA and DSA.

Authors:  F Stacul; S Gava; M Belgrano; S Cernic; L Pagnan; F Pozzi Mucelli; M A Cova
Journal:  Radiol Med       Date:  2008-05-15       Impact factor: 3.469

8.  Noncontrast-enhanced renal angiography using multiple inversion recovery and alternating TR balanced steady-state free precession.

Authors:  Hattie Z Dong; Pauline W Worters; Holden H Wu; R Reeve Ingle; Shreyas S Vasanawala; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2012-11-21       Impact factor: 4.668

9.  Hemodynamic study of unenhanced magnetic resonance angiography using spatial labeling with multiple inversion pulses sequence: a phantom study.

Authors:  Xiao Chen; Xiaoyan Meng; Di Zhu; Xianlun Zou; Yaqi Shen; Zhen Li; Jian Peng; Daoyu Hu
Journal:  Quant Imaging Med Surg       Date:  2021-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.