Literature DB >> 14988883

Carotid angioplasty under cerebral protection with the PercuSurge GuardWire System.

Michel Henry1, Antonios Polydorou, Isabelle Henry, Adamantia Polydorou, Michel Hugel.   

Abstract

The purpose of this study was to examine the possible beneficial effect of the PercuSurge GuardWire cerebral protection device based on balloon occlusion of the distal internal carotid artery and debris aspiration for patients undergoing carotid artery stenting (CAS). A total of 268 CAS procedures were attempted under cerebral protection using the PercuSurge GuardWire system in 242 patients (194 men; mean age, 71.2 +/- 9.4 years; range, 40-91). The lesions were mainly atherosclerotic; 64% were symptomatic. Technical success was 99.3%. All lesions were stented except three postangioplasty restenoses. Prophylactic occlusion during balloon dilatation and stenting was well tolerated in 255 patients (95.9%). Microscopic analysis of the aspirated blood showed different types of particles numbering between 7 and 145 per procedure, with a mean diameter of 250 microm (mean, 56-2,652 microm). The 30-day stroke and death rate was 2.3%, with four periprocedural complications at < 48 hr (one retinal embolism and three transient ischemic attacks), one intracerebral hemorrhage at 3 days, and one death of cardiac failure at 3 weeks. This technique appears safe and efficient with a low rate of periprocedural embolic events. Protection devices seem indispensable to perform CAS and expand the applicability of the procedure. Randomized studies (surgery vs. CAS with and without cerebral protection) are awaited. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 14988883     DOI: 10.1002/ccd.10776

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  5 in total

1.  Angioscopic observation during carotid angioplasty with stent placement.

Authors:  Hiroshi Tanemura; Seiji Hatazaki; Fumio Asakura; Kenji Kawaguchi; Keita Kuraishi; Naoki Toma; Hiroshi Sakaida; Masayuki Maeda; Waro Taki
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

2.  Use of Embolic Protection Devices in Peripheral Interventions.

Authors:  Martin G Radvany
Journal:  Interv Cardiol       Date:  2017-05

Review 3.  Intravascular ultrasound: principles and cerebrovascular applications.

Authors:  H Zacharatos; A E Hassan; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-04       Impact factor: 3.825

4.  Multicenter evaluation of a self-expanding carotid stent system with distal protection in the treatment of carotid stenosis.

Authors:  M D Hill; W Morrish; G Soulez; A Nevelsteen; G Maleux; C Rogers; K E Hauptmann; A Bonafé; R Beyar; L Gruberg; J Schofer
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

5.  Comparison of dual protection and distal filter protection as a distal embolic protection method during carotid artery stenting: a single-center carotid artery stenting experience.

Authors:  Yosuke Kajihara; Shigeyuki Sakamoto; Yoshihiro Kiura; Kazutoshi Mukada; Takahiro Chaki; Shiro Kajihara; Kaoru Kurisu
Journal:  Neurosurg Rev       Date:  2015-05-09       Impact factor: 3.042

  5 in total