Gaussian approximation in the theory of MR signal formation in the presence of structure-specific magnetic field inhomogeneities. Effects of impermeable susceptibility inclusions.

Alexander L Sukstanskii1, Dmitriy A Yablonskiy.   

Abstract

A detailed theoretical description of the signal formation in the presence of mesoscopic structure-specific magnetic field inhomogeneities is presented in the framework of the Gaussian phase distribution approximation for two geometrical models of the field inhomogeneity sources--impermeable spheres and infinitely long cylinders. Analytical expressions for free induction decay (FID) and spin echo (SE) signal attenuation functions Gamma(t) approximately -1nS(t) are obtained and comparison with the case of unrestricted diffusion (susceptibility inclusions with freely permeable surfaces) is provided. For short times, the leading term in the FID signal attenuation function is proportional to t2 similar to the case of unrestricted diffusion; the next term behaves as t3 as compared to t 5/2 for the "permeable" case. For the SE signal, the leading term is proportional to t3 as compared to t 5/2 for unrestricted diffusion. It is shown that the t3 approximation can be used for an adequate description of the SE signal only for extremely short times compared to a characteristic diffusion time. In the long-time limit, the attenuation function in the impermeable and permeable sphere model contains not only terms linear in time, but also important terms proportional to t 1/2. In the cylindrical geometry, the leading term in the long-time expansion of the attenuation function is proportional to t 1n t for both the permeable and impermeable models. Application to description of MR in biological tissues signal in the presence of blood vessel networks and contrast agents is discussed. The validity criterion of the Gaussian approximation is also proposed.

Mesh:

Year:  2004        PMID: 14987599     DOI: 10.1016/j.jmr.2003.11.006

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  18 in total

1.  Optimization strategies for evaluation of brain hemodynamic parameters with qBOLD technique.

Authors:  Xiaoqi Wang; Alexander L Sukstanskii; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2012-05-23       Impact factor: 4.668

2.  Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state.

Authors:  Xiang He; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

Review 3.  Transverse NMR relaxation in biological tissues.

Authors:  Valerij G Kiselev; Dmitry S Novikov
Journal:  Neuroimage       Date:  2018-06-07       Impact factor: 6.556

4.  MR susceptibility imaging.

Authors:  Jeff Duyn
Journal:  J Magn Reson       Date:  2012-11-29       Impact factor: 2.229

5.  Dispersion of relaxation rates in the rotating frame under the action of spin-locking pulses and diffusion in inhomogeneous magnetic fields.

Authors:  John T Spear; Zhongliang Zu; John C Gore
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

6.  Quantitative theory for the transverse relaxation time of blood water.

Authors:  Wenbo Li; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2020-02-05       Impact factor: 4.044

Review 7.  On modeling.

Authors:  Dmitry S Novikov; Valerij G Kiselev; Sune N Jespersen
Journal:  Magn Reson Med       Date:  2018-03-01       Impact factor: 4.668

8.  What dominates the time dependence of diffusion transverse to axons: Intra- or extra-axonal water?

Authors:  Hong-Hsi Lee; Els Fieremans; Dmitry S Novikov
Journal:  Neuroimage       Date:  2017-12-16       Impact factor: 6.556

9.  Fast and robust measurement of microstructural dimensions using temporal diffusion spectroscopy.

Authors:  Hua Li; John C Gore; Junzhong Xu
Journal:  J Magn Reson       Date:  2014-02-19       Impact factor: 2.229

10.  On the role of neuronal magnetic susceptibility and structure symmetry on gradient echo MR signal formation.

Authors:  Alexander L Sukstanskii; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2013-02-04       Impact factor: 4.668