Literature DB >> 14986194

Validation of the MetaMax II portable metabolic measurement system.

P U Larsson1, K M E Wadell, E J I Jakobsson, L U Burlin, K B Henriksson-Larsén.   

Abstract

The purpose of this study was to investigate the validity of the MetaMax II portable metabolic measurement system against the Douglas Bag technique. Nine recreationally active male subjects were included in a validation at 100 W, 10 well-trained male subjects at 200 W and 10 well-trained males at 250 W and at maximal exercise (volitional fatigue at a mean workload of 325 W). All testing was performed on an electronically braked bicycle at 60 rpm. At 100 W, the influence on MetaMax II measurements of adding a Douglas Bag breathing valve in series to the MetaMax II was investigated. The oxygen uptake was, for the MetaMax II, at 100 W mean 0.03 l x min (-1) higher (p < 0.01), at 200 W mean 0.02 l x min (-1) (n. s.) lower, at 250 W mean 0.04 l x min (-1) (n. s.) higher, and at 325 W mean 0.11 l x min (-1) (p < 0.05) higher. The carbon dioxide excretion was, for the MetaMax II, at 100 W mean 0.06 l x min (-1) (p < 0.01) lower, at 200 W mean 0.11 l x min (-1) (p < 0.05) lower, at 250 W mean 0.03 l x min (-1) (n. s.) lower, and at 325 W mean 0.16 l x min (-1) (p < 0.05) lower. The addition of a breathing valve in series to the MetaMax II resulted in lower breathing frequency, a higher ventilated tidal volume, and an affected gas measurement validation. In conclusion, the MetaMax II was found to be valid for metabolic gas measurements between 100 and at least 250 W.

Entities:  

Mesh:

Year:  2004        PMID: 14986194     DOI: 10.1055/s-2004-819953

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  19 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

2.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

3.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.

Authors:  Hans Rosdahl; Lennart Gullstrand; Jane Salier-Eriksson; Patrik Johansson; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2009-12-31       Impact factor: 3.078

4.  A pilot study comparing two field tests with the treadmill run test in soccer players.

Authors:  Abdul Rashid Aziz; Frankie H Y Tan; Kong Chuan Teh
Journal:  J Sports Sci Med       Date:  2005-06-01       Impact factor: 2.988

Review 5.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

6.  Test-retest reliability and minimum detectable change using the K4b2: oxygen consumption, gait efficiency, and heart rate for healthy adults during submaximal walking.

Authors:  Benjamin J Darter; Kelly M Rodriguez; Jason M Wilken
Journal:  Res Q Exerc Sport       Date:  2013-06       Impact factor: 2.500

7.  Prediction of upper extremity peak oxygen consumption from heart rate during submaximal arm cycling in young and middle-aged adults.

Authors:  Jan Helgerud; Britt Elin Øiestad; Eivind Wang; Jan Hoff
Journal:  Eur J Appl Physiol       Date:  2019-10-04       Impact factor: 3.078

8.  Reliability of the VmaxST portable metabolic measurement system.

Authors:  J Blessinger; B Sawyer; C Davis; B A Irving; A Weltman; G Gaesser
Journal:  Int J Sports Med       Date:  2008-07-23       Impact factor: 3.118

9.  High Energetic Demand of Elite Rowing - Implications for Training and Nutrition.

Authors:  Kay Winkert; Juergen M Steinacker; Karsten Koehler; Gunnar Treff
Journal:  Front Physiol       Date:  2022-04-19       Impact factor: 4.755

10.  International Physical Activity Questionnaire (IPAQ) and New Zealand Physical Activity Questionnaire (NZPAQ): a doubly labelled water validation.

Authors:  Ralph Maddison; Cliona Ni Mhurchu; Yannan Jiang; Stephen Vander Hoorn; Anthony Rodgers; Carlene Mm Lawes; Elaine Rush
Journal:  Int J Behav Nutr Phys Act       Date:  2007-12-03       Impact factor: 6.457

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.