Literature DB >> 14983944

Gadolinium magnetic resonance contrast agents produce analytic interference in multiple serum assays.

Kerry A S Proctor1, Lokinendi V Rao, William L Roberts.   

Abstract

Gadolinium magnetic resonance contrast agents are known to interfere with some clinical chemistry tests, particularly colorimetric assays for serum calcium. We studied the effects of 4 agents, gadodiamide, gadoversetamide, gadopentetate dimeglumine, and gadoteridol, for interference with multiple serum assays. Gadodiamide and gadoversetamide produced clinically significant negative interference with colorimetric assays for serum angiotensin-converting enzyme, calcium, and zinc. These agents produced clinically significant positive interference in magnesium and total iron binding capacity assays and both positive and negative interference in iron assays. Gadopentetate dimeglumine produced a negative interference with iron assays, and gadopentetate dimeglumine and gadoteridol produced negative interference with a colorimetric zinc assay. Caution should be exercised when using colorimetric assays for angiotensin-converting enzyme, calcium, iron, magnesium, total iron binding capacity, and zinc in serum samples from patients who have recently received magnetic resonance contrast agents. In general, gadodiamide and gadoversetamide are more likely to produce a clinically significant interference than gadopentetate dimeglumine and gadoteridol. Likewise, certain analytic methods are more prone to interference, while others not affected.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14983944     DOI: 10.1309/MGA3-LC4X-8CGL-X9CH

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  8 in total

Review 1.  Contrast media: interactions with other drugs and clinical tests.

Authors:  Sameh K Morcos; Henrik S Thomsen; C M Exley
Journal:  Eur Radiol       Date:  2005-01-26       Impact factor: 5.315

2.  Confounding Hyponatremia and Hypochloremia in a Cancer Patient.

Authors:  Patrick Erdman; Lakshmi Ramanathan; Martin Fleisher; Melissa Pessin
Journal:  J Appl Lab Med       Date:  2020-05-01

3.  New method for calcium on the ADVIA analyzer is free from interference of gadolinium-type contrast agents.

Authors:  Pradip Datta; Amitava Dasgupta
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

Review 4.  Biochemical safety profiles of gadolinium-based extracellular contrast agents and nephrogenic systemic fibrosis.

Authors:  Hale Ersoy; Frank J Rybicki
Journal:  J Magn Reson Imaging       Date:  2007-11       Impact factor: 4.813

5. 

Authors:  Imene Ben Jdidia; Kaouther Zribi; Meriam Boubaker; Amira Brahem; Mouna Sayadi; Marwa Tlijani; Zahra Saidani; Amani Cherif
Journal:  Can J Hosp Pharm       Date:  2021

6.  Analytical Interference by Contrast Agents in Biochemical Assays.

Authors:  Sigrid Otnes; Niels Fogh-Andersen; Janne Rømsing; Henrik S Thomsen
Journal:  Contrast Media Mol Imaging       Date:  2017-04-10       Impact factor: 3.161

Review 7.  Interference of medical contrast media on laboratory testing.

Authors:  Giuseppe Lippi; Massimo Daves; Camilla Mattiuzzi
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

8.  Analytical interference in serum iron determination reveals iron versus gadolinium transmetallation with linear gadolinium-based contrast agents.

Authors:  Nathalie Fretellier; Nathalie Poteau; Cécile Factor; Jean-François Mayer; Christelle Medina; Marc Port; Jean-Marc Idée; Claire Corot
Journal:  Invest Radiol       Date:  2014-12       Impact factor: 6.016

  8 in total