Literature DB >> 14980836

Repair of Superior Vena Caval Perforation during Pacemaker Placement with Video-Assisted Limited Thoracotomy.

James I. Fann1, J. Edwin Atwood, Thomas A. Burdon.   

Abstract

Abstract We report a case of a patient who sustained superior vena cava perforation just proximal to the innominate-caval confluence during pacemaker implantation. Because this complication was recognized early and the dilator was left in place, the patient remained hemodynamically stable and successfully underwent a videoscopically assisted repair of the superior vena caval perforation through a limited thoracotomy incision.

Entities:  

Year:  2004        PMID: 14980836     DOI: 10.1532/hsf.555

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  1 in total

1.  Pacemaker lead malposition in the left atrial roof is masked by normal pacing thresholds.

Authors:  Claus Rath; Martin Andreas; Caesar Khazen; Dominik Wiedemann; Andreas Habertheuer; Alfred Kocher
Journal:  J Cardiothorac Surg       Date:  2014-03-20       Impact factor: 1.637

  1 in total