Literature DB >> 14979347

Validation and implementation of the PowerPlex 16 BIO System STR multiplex for forensic casework.

Susan A Greenspoon1, Jeffrey D Ban, Lourdes Pablo, Cecelia A Crouse, Frank G Kist, Chris S Tomsey, Alex L Glessner, Lisa R Mihalacki, Teresa M Long, Bruce J Heidebrecht, Cathryn A Braunstein, David A Freeman, Carl Soberalski, Bruesehoff Nathan, Ashima S Amin, Elizabeth K Douglas, James W Schumm.   

Abstract

The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14979347

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  5 in total

1.  Haplotyping of STR cluster DXS6801-DXS6809-DXS6789 on Xq21 provides a powerful tool for kinship testing.

Authors:  Reinhard Szibor; Sandra Hering; Eberhard Kuhlisch; Ines Plate; Susanne Demberger; Michael Krawczak; Jeanett Edelmann
Journal:  Int J Legal Med       Date:  2005-08-11       Impact factor: 2.686

2.  Optimisation of forensic genetics procedures used in disputed paternity testing: adjustment of the PCR reaction volume.

Authors:  Damir Marjanović; Narcisa Bakal; Lejla Kovacević; Melisa Hodzić; Anja Haverić; Sanin Haverić; Slavica Ibrulj; Adaleta Durmić
Journal:  Bosn J Basic Med Sci       Date:  2006-05       Impact factor: 3.363

3.  Validation of a short tandem repeat multiplex typing system for genetic individualization of domestic cat samples.

Authors:  Nikia Coomber; Victor A David; Stephen J O'Brien; Marilyn Menotti-Raymond
Journal:  Croat Med J       Date:  2007-08       Impact factor: 1.351

4.  Short-read, high-throughput sequencing technology for STR genotyping.

Authors:  Daniel M Bornman; Mark E Hester; Jared M Schuetter; Manjula D Kasoji; Angela Minard-Smith; Curt A Barden; Scott C Nelson; Gene D Godbold; Christine H Baker; Boyu Yang; Jacquelyn E Walther; Ivan E Tornes; Pearlly S Yan; Benjamin Rodriguez; Ralf Bundschuh; Michael L Dickens; Brian A Young; Seth A Faith
Journal:  Biotech Rapid Dispatches       Date:  2012-04

5.  Effects of storage time on DNA profiling success from archived latent fingerprint samples using an optimised workflow.

Authors:  Sydney I Menchhoff; April D Solomon; Jordan O Cox; Madison E Hytinen; Marilyn T Miller; Tracey Dawson Cruz
Journal:  Forensic Sci Res       Date:  2020-08-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.