Noninvasive measurement of intrapulmonary shunting.

Philip J Peyton1, Gavin J B Robinson, Peter R McCall, Bruce Thompson.   

Abstract

OBJECTIVE: To investigate the accuracy and precision of a noninvasive approach to measurement of pulmonary shunt fraction using simultaneous application of 2 fundamental respiratory mixing equations: the direct Fick equation for oxygen and the shunt equation of Berggren. This can be performed without mixed venous blood sampling and requires measurement of oxygen uptake and pulmonary blood flow.
DESIGN: Comparison with invasive shunt fraction measured using mixed venous blood sampling and with estimated shunt fraction using an assumed arteriovenous O(2) content difference.
SETTING: Major teaching hospital. PARTICIPANTS: Nine patients undergoing anesthesia for cardiac surgery.
INTERVENTIONS: Pulmonary blood flow was measured using an indirect Fick technique (nitrous oxide throughflow) and by bolus thermodilution for comparison.
MEASUREMENTS AND MAIN RESULTS: The mean shunt fraction measured by the invasive method was 0.145 (range 0.057-0.263). When pulmonary blood flow was measured using an indirect Fick technique (nitrous oxide throughflow), the absolute mean bias for noninvasive shunt fraction was -0.005 with a standard deviation of 0.012. Correlation was excellent (r(2) = 0.95, p < 0.001). Agreement was less precise when pulmonary blood flow was measured using thermodilution (mean bias + 0.001 with a standard deviation of 0.018).
CONCLUSIONS: The noninvasive method is an accurate substitute for invasive shunt fraction measurement with mixed venous blood sampling.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14973799     DOI: 10.1053/j.jvca.2003.10.010

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  4 in total

1.  Performance of a second generation pulmonary capnotracking system for continuous monitoring of cardiac output.

Authors:  Philip J Peyton; Monique Kozub
Journal:  J Clin Monit Comput       Date:  2018-02-08       Impact factor: 2.502

Review 2.  New generation continuous cardiac output monitoring from carbon dioxide elimination.

Authors:  Philip J Peyton; Mats Wallin; Magnus Hallbäck
Journal:  BMC Anesthesiol       Date:  2019-02-26       Impact factor: 2.217

3.  Validation of intracardiac shunt using thoracic bioimpedance and inert gas rebreathing in adults before and after percutaneous closure of atrial septal defect in a cardiology research unit: study protocol.

Authors:  Laura Filaire; Aurelie Chalard; Hélène Perrault; Romain Trésorier; Jean-René Lusson; Bruno Pereira; Frederic Costes; Claire Dauphin; Ruddy Richard
Journal:  BMJ Open       Date:  2019-05-27       Impact factor: 2.692

4.  Development of severe intrapulmonary shunting in a patient with carcinoid heart disease after closure of a persistent foramen ovale: a case report.

Authors:  Dominik Schüttler; Konstantinos Mourouzis; Christoph J Auernhammer; Konstantinos D Rizas
Journal:  Eur Heart J Case Rep       Date:  2021-12-04