Abstract

Many international protocols related to RMI-QC program are focused on acquisition methods and analysis of several image quality parameters but rarely normality ranges or measurement frequencies are presented. To address this problem we investigated the variability of many magnetic resonance imaging (MRI) systems with the set-up of multicenter trial. The trial was set up to investigate short-and mid-term variability of two fundamental nongeometric image quality parameters: signal-to-noise (SNR) and integral percent uniformity (U%). Ten centers (12 devices) participated to data collection consisting of a three-step-protocol. First, 10 consecutive images of a phantom were collected with a spin echo sequence. As second step the series collection was repeated 24 h later. Finally a single image acquisition was performed twice a week for 5 weeks. The analysis of results allowed us to define a "physiological" variability of +/-3% of the reference level for both parameters and to conclude that a weekly measurement is adequate to detect relevant variations of device performance.

Mesh:

Year:  2004        PMID: 14972398     DOI: 10.1016/j.mri.2003.04.001

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Diffusion tensor imaging properties and neurobehavioral outcomes in children with hydrocephalus.

Authors:  W Yuan; R C McKinstry; J S Shimony; M Altaye; S K Powell; J M Phillips; D D Limbrick; S K Holland; B V Jones; A Rajagopal; S Simpson; D Mercer; F T Mangano
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-16       Impact factor: 3.825

2.  Design and Application of a New Automated Fluidic Visceral Stimulation Device for Human fMRI Studies of Interoception.

Authors:  Behnaz Jarrahi; Roger Gassert; Johann Wanek; Lars Michels; Ulrich Mehnert; Spyros S Kollias
Journal:  IEEE J Transl Eng Health Med       Date:  2016-03-31       Impact factor: 3.316

3.  Establishment and results of a magnetic resonance quality assurance program for the pediatric brain tumor consortium.

Authors:  Robert V Mulkern; Peter Forbes; Kevin Dewey; Stravoula Osganian; Maureen Clark; Sharon Wong; Uma Ramamurthy; Larry Kun; Tina Young Poussaint
Journal:  Acad Radiol       Date:  2008-09       Impact factor: 3.173

4.  Measurement of MRI scanner performance with the ADNI phantom.

Authors:  Jeffrey L Gunter; Matt A Bernstein; Brett J Borowski; Chadwick P Ward; Paula J Britson; Joel P Felmlee; Norbert Schuff; Michael Weiner; Clifford R Jack
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Design and application of an MR reference phantom for multicentre lung imaging trials.

Authors:  Simon M F Triphan; Jürgen Biederer; Kerstin Burmester; Iven Fellhauer; Claus F Vogelmeier; Rudolf A Jörres; Hans-Ulrich Kauczor; Claus P Heußel; Mark O Wielpütz; Bertram J Jobst
Journal:  PLoS One       Date:  2018-07-05       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.