Literature DB >> 14970136

Off-pump coronary artery bypass surgery: physiology and anaesthetic management.

P-G Chassot1, P van der Linden, M Zaugg, X M Mueller, D R Spahn.   

Abstract

Increasing interest is being shown in beating heart (off-pump) coronary artery surgery (OPCAB) because, compared with operations performed with cardiopulmonary bypass, OPCAB surgery may be associated with decreased postoperative morbidity and reduced total costs. Its appears to produce better results than conventional surgery in high-risk patient populations, elderly patients, and those with compromised cardiac function or coagulation disorders. Recent improvements in the technique have resulted in the possibility of multiple-vessel grafting in all coronary territories, with a graft patency comparable with conventional surgery. During beating-heart surgery, anaesthetists face two problems: first, the maintenance of haemodynamic stability during heart enucleation necessary for accessing each coronary artery; and second, the management of intraoperative myocardial ischaemia when coronary flow must be interrupted during grafting. The anaesthetic technique is less important than adequate management of these two major constraints. However, experimental and recent clinical data suggest that volatile anaesthetics have a marked cardioprotective effect against ischaemia, and might be specifically indicated. OPCAB surgery requires team work between anaesthetists and surgeons, who must be aware of each other's constraints. Some surgical aspects of the operation are reviewed along with physiological and anaesthetic data.

Entities:  

Mesh:

Year:  2004        PMID: 14970136     DOI: 10.1093/bja/aeh064

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  14 in total

1.  Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.

Authors:  Youn Joung Cho; Chang-Hoon Koo; Tae Kyong Kim; Deok Man Hong; Yunseok Jeon
Journal:  J Clin Monit Comput       Date:  2015-10-01       Impact factor: 2.502

Review 2.  Off-pump coronary artery bypass: techniques, pitfalls, and results.

Authors:  Tadashi Tashiro; Hideichi Wada; Masaru Nishimi; Noritoshi Minematsu
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-06-18

3.  The effect of milrinone on the right ventricular function in patients with reduced right ventricular function undergoing off-pump coronary artery bypass graft surgery.

Authors:  Jong Hwa Lee; Young Jun Oh; Yon Hee Shim; Yong Woo Hong; Gijong Yi; Young Lan Kwak
Journal:  J Korean Med Sci       Date:  2006-10       Impact factor: 2.153

4.  Risk of renal dysfunction after less invasive multivessel coronary artery bypass grafting.

Authors:  Soroosh Kiani; Alex K Brown; Dinesh J Kurian; Stanislav Henkin; Mary M Flynn; Nannan Thirumavalavan; Pranjal H Desai; Robert S Poston
Journal:  Innovations (Phila)       Date:  2012 May-Jun

5.  Brain function monitoring during off-pump cardiac surgery: a case report.

Authors:  Paolo Zanatta; Enrico Bosco; Piero Di Pasquale; Agarwal Nivedita; Carlo Valfrè; Carlo Sorbara
Journal:  Cases J       Date:  2008-08-15

6.  The degree of newly emerging mitral regurgitation during off-pump coronary artery bypass is predicted by preoperative left ventricular function.

Authors:  Toshimasa Akazawa; Hirotaka Iizuka; Miyuki Aizawa; Kengo Warabi; Masayuki Ohshima; Atushi Amano; Eiichi Inada
Journal:  J Anesth       Date:  2008-02-27       Impact factor: 2.078

7.  The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function.

Authors:  Youn Yi Jo; Jong Wook Song; Young Chul Yoo; Ji Young Park; Jae Kwang Shim; Young Lan Kwak
Journal:  Korean J Anesthesiol       Date:  2011-04-26

8.  The effect of milrinone on the intraoperative hemodynamics during off-pump coronary bypass surgery in patients with an elevated echocardiographic index of the ventricular filling pressure.

Authors:  Jong Wook Song; Youn Yi Jo; Na Hyung Jun; Ha Kyoung Kim; Young Lan Kwak
Journal:  Korean J Anesthesiol       Date:  2011-03-30

9.  Epidural anesthesia and postoperative analgesia with ropivacaine and fentanyl in off-pump coronary artery bypass grafting: a randomized, controlled study.

Authors:  Mikhail Y Kirov; Alexey V Eremeev; Alexey A Smetkin; Lars J Bjertnaes
Journal:  BMC Anesthesiol       Date:  2011-09-18       Impact factor: 2.217

10.  Intensified thermal management for patients undergoing transcatheter aortic valve implantation (TAVI).

Authors:  Ivo F Brandes; Marc Jipp; Aron F Popov; Ralf Seipelt; Michael Quintel; Anselm Bräuer
Journal:  J Cardiothorac Surg       Date:  2011-09-25       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.