Literature DB >> 14967268

Effect of optic edge design and haptic angulation on postoperative intraocular lens position change.

Vanessa Petternel1, Rupert Menapace, Oliver Findl, Barbara Kiss, Matthias Wirtitsch, Georg Rainer, Wolfgang Drexler.   

Abstract

PURPOSE: To assess the effect of optic edge design and optic-haptic angulation of open-loop intraocular lenses (IOLs) on postoperative axial movement and the final position of the optic by measuring the anterior chamber depth (ACD) during the first postoperative year using partial coherence interferometry (PCI).
SETTING: Department of Ophthalmology, Vienna General Hospital, Institute of Medical Physics, University of Vienna, Vienna, Austria.
METHODS: In study 1, a 3-piece silicone IOL with nonangulated modified C-loop haptics (MicroSil, Dr. Schmidt) was implanted in 78 eyes of 39 patients; patients were randomized to receive a round-edged optic IOL in 1 eye and a sharp-edged optic IOL in the other eye. The ACD was measured by PCI 1 day, 1 week, 3 months, and 1 year after surgery. In study 2, a foldable, 3-piece acrylic IOL with modified 10-degree angulated J-loop haptics (AcrySof MA60BM, Alcon) was implanted in 32 eyes of 32 patients. The ACD was measured by PCI 1 day, 1 week, and 3 months after surgery.
RESULTS: In eyes with a nonangulated silicone IOL, there was a significant postoperative change in ACD with both sharp-edged and round-edged designs (P<.01). There was forward movement of both IOL designs in the first week, with no significant difference between the 2 models. From 1 week to 3 months, there was backward movement of IOLs of both designs, with the sharp-edged IOL moving a significantly greater amount (P<.001). From 3 months to 1 year, IOLs with both optic edge designs moved slightly backward. Sixty-six percent of angulated IOLs showed continuous but variable forward movement and 34%, backward movement.
CONCLUSIONS: Optic edge design influenced postoperative axial optic movement and thus had an impact on the development of postoperative refraction (refractive shift, deviation from target refraction). The influence of optic-haptic angulation proved to be significantly greater and more variable than edge design.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14967268     DOI: 10.1016/S0886-3350(03)00556-X

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  12 in total

1.  Accommodative lens refilling in rhesus monkeys.

Authors:  Steven A Koopmans; Thom Terwee; Adrian Glasser; Mark Wendt; Abhiram S Vilupuru; Abhiram S Vilipuru; Theo G van Kooten; Sverker Norrby; Henk J Haitjema; Aart C Kooijman
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-07       Impact factor: 4.799

2.  Effect of the hydrophilicity of acrylic intraocular lens material and haptic angulation on anterior capsule opacification.

Authors:  Lorenz Vock; Michael Georgopoulos; Thomas Neumayer; Wolf Buehl; Oliver Findl
Journal:  Br J Ophthalmol       Date:  2006-11-15       Impact factor: 4.638

3.  Refractive outcome of trocar-assisted sutureless scleral fixation with 3-piece intraocular lenses.

Authors:  Veysel Aykut; Fehim Esen; Fatma Sali; Halit Oguz
Journal:  Int Ophthalmol       Date:  2021-04-07       Impact factor: 2.031

4.  Intraocular lens power estimation in combined phacoemulsification and pars plana vitrectomy in eyes with epiretinal membranes: a case-control study.

Authors:  Min Kim; Hyoung Eun Kim; Dong Hyun Lee; Hyoung Jun Koh; Sung Chul Lee; Sung Soo Kim
Journal:  Yonsei Med J       Date:  2015-05       Impact factor: 2.759

5.  Anterior Chamber Depth Change Following Cataract Surgery in Pseudoexfoliation Syndrome; a Preliminary Study.

Authors:  Mohammad Reza Fallah Tafti; Hossein Abdollah Beiki; S Farzad Mohammadi; Golshan Latifi; Elham Ashrafi; Zahra Fallah Tafti
Journal:  J Ophthalmic Vis Res       Date:  2017 Apr-Jun

6.  Comparative evaluation of refractive outcomes after implantation of two types of intraocular lenses with different diopter intervals (0.25 diopter versus 0.50 diopter).

Authors:  Minjung Kim; Youngsub Eom; Jong Suk Song; Hyo Myung Kim
Journal:  BMC Ophthalmol       Date:  2018-07-18       Impact factor: 2.209

7.  Postoperative Refractive Prediction Error Measured by Optical and Acoustic Biometry after Phacovitrectomy for Rhegmatogenous Retinal Detachment without Macular Involvement.

Authors:  Masashi Sakamoto; Izumi Yoshida; Takahiro Sodeno; Asao Sakai; Hidetaka Masahara; Takatoshi Maeno
Journal:  J Ophthalmol       Date:  2019-05-02       Impact factor: 1.909

8.  Comparison of postoperative axial stability of intraocular lens and capsulotomy parameters between precision pulse capsulotomy and continuous curvilinear capsulotomy: A prospective cohort study.

Authors:  Seung Pil Bang; Jong Hwa Jun
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

9.  Topical vs Peribulbar Anesthesia: Comparison of Anterior Chamber Depth and the Resultant Visual Outcome After Phacoemulsification.

Authors:  Mayuresh P Naik; Harinder Singh Sethi; Amita Yadav
Journal:  Clin Ophthalmol       Date:  2020-11-03

10.  Epidemiological evaluation of YAG capsulotomy incidence for posterior capsule opacification in various intraocular lenses in Japanese eyes.

Authors:  Yutaro Nishi; Tomohiro Ikeda; Kayo Nishi; Osamu Mimura
Journal:  Clin Ophthalmol       Date:  2015-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.