Literature DB >> 14962804

Mechanotransduction in the cortical bone is most efficient at loading frequencies of 5-10 Hz.

S J Warden1, C H Turner.   

Abstract

A dose-response relationship has been shown between loading frequency and cortical bone adaptation for frequencies of up to 10 Hz, and is presumed to persist with further increases in frequency. Studies herein aimed to investigate cortical bone adaptation to loading frequencies of 1, 5, 10, 20 and 30 Hz. Two studies were performed in adult C57BL/6 mice using the ulna axial compression-loading model. In the first study, the histomorphometric response of the ulna was studied when loaded for 120 cycles day(-1) for 3 days at one of the five frequencies and one of two load magnitudes (1.5 or 2.0 N). In the second study, the changes in ulna geometry and mechanical properties were studied following loading for 5 min day(-1), 3 days week(-1) for 4 weeks at one of the five frequencies and one of two load magnitudes (1.0 or 1.6 N). Preliminary strain gauge measurements showed that frequency had no effect on mechanical strain per unit load. In study 1, loading frequency significantly influenced bone adaptation when loading at 2.0 N, with loading at 10 Hz resulting in significantly greater adaptation than with loading at other frequencies. In study 2, loading frequency significantly influenced the change in geometry when loading at 1.6 N, with loading at 5, 10 or 30 Hz resulting in significantly greater change than with loading at 1 Hz. Loading at 5 Hz also resulted in significantly greater change than with loading at 20 Hz. No frequency effect was found on any of the mechanical properties at either load. Overall, we found cortical bone adaptation to mechanical loading to increase with increasing loading frequency up to 5-10 Hz and to plateau with frequencies beyond 10 Hz. The mechanism for this nonlinear frequency response is not known; however, based on strain gauge measurements, we do not believe it resulted from dampening associated with high frequency loading through the flexed carpal joint. The obtained findings may relate to the mechanism of mechanotransduction within the bone. This requires further investigation.

Entities:  

Mesh:

Year:  2004        PMID: 14962804     DOI: 10.1016/j.bone.2003.11.011

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  39 in total

1.  The relationship between bone mechanical properties and ground reaction forces in normal and hypermuscular mice.

Authors:  Daniel Schmitt; Ann C Zumwalt; Mark W Hamrick
Journal:  J Exp Zool A Ecol Genet Physiol       Date:  2010-07-01

2.  In vivo assessment of the effect of controlled high- and low-frequency mechanical loading on peri-implant bone healing.

Authors:  Xiaolei Zhang; Katleen Vandamme; Antonia Torcasio; Toru Ogawa; G Harry van Lenthe; Ignace Naert; Joke Duyck
Journal:  J R Soc Interface       Date:  2012-01-25       Impact factor: 4.118

3.  Design and analysis of a novel mechanical loading machine for dynamic in vivo axial loading.

Authors:  James Macione; Sterling Nesbitt; Vaibhav Pandit; Shiva Kotha
Journal:  Rev Sci Instrum       Date:  2012-02       Impact factor: 1.523

4.  Evidence for an additional effect of whole-body vibration above resistive exercise alone in preventing bone loss during prolonged bed rest.

Authors:  D L Belavý; G Beller; G Armbrecht; F H Perschel; R Fitzner; O Bock; H Börst; C Degner; U Gast; D Felsenberg
Journal:  Osteoporos Int       Date:  2010-09-03       Impact factor: 4.507

5.  Quantification of Lacunar-Canalicular Interstitial Fluid Flow Through Computational Modeling of Fluorescence Recovery After Photobleaching.

Authors:  Ronald Y Kwon; John A Frangos
Journal:  Cell Mol Bioeng       Date:  2010-09-01       Impact factor: 2.321

6.  Differential effects of strength versus power training on bone mineral density in postmenopausal women: a 2-year longitudinal study.

Authors:  Simon von Stengel; Wolfgang Kemmler; Willi A Kalender; Klaus Engelke; Dirk Lauber
Journal:  Br J Sports Med       Date:  2007-06-05       Impact factor: 13.800

7.  Dynamic fluid flow induced mechanobiological modulation of in situ osteocyte calcium oscillations.

Authors:  Minyi Hu; Guo-Wei Tian; Daniel E Gibbons; Jian Jiao; Yi-Xian Qin
Journal:  Arch Biochem Biophys       Date:  2015-06-01       Impact factor: 4.013

8.  Numerical modeling of long bone adaptation due to mechanical loading: correlation with experiments.

Authors:  Natarajan Chennimalai Kumar; Jonathan A Dantzig; Iwona M Jasiuk; Alex G Robling; Charles H Turner
Journal:  Ann Biomed Eng       Date:  2009-12-15       Impact factor: 3.934

9.  Joint loading-driven bone formation and signaling pathways predicted from genome-wide expression profiles.

Authors:  Ping Zhang; Charles H Turner; Hiroki Yokota
Journal:  Bone       Date:  2009-02-07       Impact factor: 4.398

10.  Effects of low-magnitude, high-frequency mechanical stimulation in the rat osteopenia model.

Authors:  S Sehmisch; R Galal; L Kolios; M Tezval; C Dullin; S Zimmer; K M Stuermer; E K Stuermer
Journal:  Osteoporos Int       Date:  2009-03-13       Impact factor: 4.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.