Literature DB >> 14961738

Development of a solid-phase microextraction gas chromatography/tandem mass spectrometry method for polybrominated diphenyl ethers and polybrominated biphenyls in water samples.

M Polo1, G Gómez-Noya, J B Quintana, M Llompart, C García-Jares, R Cela.   

Abstract

Solid-phase microextraction has been applied for the first time to the determination of trace concentrations of some brominated flame-retardant compounds (BFRs) in water samples. For the development of the method, six polybrominated diphenyl ethers and two polybrominated biphenyls were considered as target analytes. The factors expected to influence the extraction process are fully discussed. Quantification has been performed by gas chromatography/tandem mass spectrometry using an ion trap mass analyzer. This is also the first time that tandem mass spectrometry is applied with these analytes. Unlike conventional methods for BFR analysis, which involve solvent extraction and several cleanup steps before gas chromatography, the proposed method uses headspace extraction and hard contamination of the chromatographic system is prevented. In addition, tandem mass spectrometry provides selectivity and sensitivity in the detection process. The method performs well achieving good linearity (R(2) > 0.997), precision, and detection limits (S/N = 3) ranging from 7.5 to 190 pg/L. The method has been applied to a variety of water samples.

Entities:  

Year:  2004        PMID: 14961738     DOI: 10.1021/ac030292x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Analysis of PBDEs in soil, dust, spiked lake water, and human serum samples by hollow fiber-liquid phase microextraction combined with GC-ICP-MS.

Authors:  Qin Xiao; Bin Hu; Jiankun Duan; Man He; Wanqing Zu
Journal:  J Am Soc Mass Spectrom       Date:  2007-07-17       Impact factor: 3.109

2.  Optimization and Simultaneous Determination of Alkyl Phenol Ethoxylates and Brominated Flame Retardants in Water after SPE and Heptafluorobutyric Anhydride Derivatization followed by GC/MS.

Authors:  Tlou B Chokwe; Jonathan O Okonkwo; Linda L Sibali; Esper J Ncube
Journal:  Chromatographia       Date:  2012-09-16       Impact factor: 2.044

3.  Instrumental methods and challenges in quantifying polybrominated diphenyl ethers in environmental extracts: a review.

Authors:  Heather M Stapleton
Journal:  Anal Bioanal Chem       Date:  2006-10       Impact factor: 4.142

  3 in total