| Literature DB >> 1489635 |
K Itoh1, H Takekawa, E Tsukamoto, K Nagao, K Nakada, S Abe, Y Kawakami, M Furudate.
Abstract
A single photon emission computed tomography (SPECT) with 201Tl chloride (Tl-201) was carried out prospectively in 50 patients with pulmonary nodules and its diagnostic value was compared with those of 67Ga citrate (Ga-67) and 99mTc-labeled hexamethylpropyleneamine-oxime (Tc-99m-HMPAO). Tl-201 SPECT provided 88% (early)-91% (delayed) sensitivity, 85% (early and delayed) specificity and 87% (early)-89% (delayed) accuracy. The sensitivity of the Tl-201 planar image was 56 (early)-62% (delayed), which was significantly lower than that of SPECT. Delayed SPECT images at 2 hour postinjection were more preferable to disclose the malignant pulmonary nodule than early SPECT images at 15 minutes postinjection. The application of SPECT with Ga-67 failed to improve the sensitivity of planar imaging for malignant pulmonary nodules. Tc-99m-HMPAO was concentrated in 62% of 13 patients with malignant pulmonary nodules, which was slightly higher than Ga-67 in 54% of 28 patients. In an analysis of the histologic types of lung cancer, the sensitivity of Tl-201 was not significantly different in all types. On the other hand, Ga-67 was positive only in 25% of 12 patients with adenocarcinoma. A combination of SPECT and Tl-201 is the best choice among routine scintigraphic techniques for depicting malignant pulmonary nodules. The Tl-201 SPECT image may play a complementary role in the characterization of pulmonary nodules which are revealed on a plain radiograph and computed tomography.Entities:
Mesh:
Substances:
Year: 1992 PMID: 1489635 DOI: 10.1007/bf03164663
Source DB: PubMed Journal: Ann Nucl Med ISSN: 0914-7187 Impact factor: 2.668