Literature DB >> 14872368

High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience.

H H Quick1, F M Vogt, S Maderwald, C U Herborn, S Bosk, S Göhde, J F Debatin, M E Ladd.   

Abstract

PURPOSE: To combine whole-body multi-station three-dimensional contrast enhanced magnetic resonance angiography (3D CE MRA) using a self-developed rolling table platform with parallel imaging strategies (PAT) in order to increase the spatial resolution of the 3D MRA data sets.
MATERIALS AND METHODS: Whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol.
RESULTS: Compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition.
CONCLUSION: The implementation of PAT into the concept of whole-body MRA enabled to increase the spatial resolution in all examined territories, which resulted in more detailed MR angiograms.

Mesh:

Substances:

Year:  2004        PMID: 14872368     DOI: 10.1055/s-2004-817623

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  12 in total

Review 1.  [Whole body MRI--diagnostic strategy of the future?].

Authors:  M Goyen; H-P Schlemmer
Journal:  Radiologe       Date:  2007-10       Impact factor: 0.635

Review 2.  Perspectives for preventive screening with total body MRI.

Authors:  Susanne C Ladd; Mark E Ladd
Journal:  Eur Radiol       Date:  2007-06-05       Impact factor: 5.315

3.  [Cost considerations for whole-body MRI and PET/CT as part of oncologic staging].

Authors:  C Plathow; M Walz; M P Lichy; P Aschoff; C Pfannenberg; H Bock; S M Eschmann; C D Claussen; H P Schlemmer
Journal:  Radiologe       Date:  2008-04       Impact factor: 0.635

Review 4.  Whole-Body MRA.

Authors:  Harald Kramer; Harald H Quick; Bernd Tombach; Stefan O Schoenberg; Joerg Barkhausen
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

5.  Parallel reconstruction using null operations.

Authors:  Jian Zhang; Chunlei Liu; Michael E Moseley
Journal:  Magn Reson Med       Date:  2011-05-20       Impact factor: 4.668

6.  [Prognostic value of cardiovascular MRI in diabetics].

Authors:  C L Schlett; R C Bertheau; H-U Kauczor; S Weckbach
Journal:  Radiologe       Date:  2015-04       Impact factor: 0.635

7.  Towards real-time cardiovascular magnetic resonance-guided transarterial aortic valve implantation: in vitro evaluation and modification of existing devices.

Authors:  Philipp Kahlert; Holger Eggebrecht; Björn Plicht; Oliver Kraff; Ian McDougall; Brad Decker; Raimund Erbel; Mark E Ladd; Harald H Quick
Journal:  J Cardiovasc Magn Reson       Date:  2010-10-13       Impact factor: 5.364

8.  Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography.

Authors:  Eric G Stinson; Eric A Borisch; Casey P Johnson; Joshua D Trzasko; Phillip M Young; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2013-07-29       Impact factor: 4.813

Review 9.  Whole-body magnetic resonance angiography at 3.0 Tesla.

Authors:  Michael Fenchel; Kambiz Nael; Achim Seeger; Ulrich Kramer; Roya Saleh; Stephan Miller
Journal:  Eur Radiol       Date:  2008-02-15       Impact factor: 7.034

10.  Clinical value of whole-body magnetic resonance imaging in health screening of general adult population.

Authors:  David Laszlo Tarnoki; Adam Domonkos Tarnoki; Antje Richter; Kinga Karlinger; Viktor Berczi; Dirk Pickuth
Journal:  Radiol Oncol       Date:  2015-03-03       Impact factor: 2.991

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.