Literature DB >> 1484676

Reproducibility of data obtained by a newly developed anterior eye segment analysis system, EAS-1000.

Y Sakamoto1, K Sasaki, Y Nakamura, N Watanabe.   

Abstract

The reproducibility of data obtained from the recently developed anterior eye segment analysis system (EAS-1000) was evaluated. 40 normal eyes and 62 cataractous eyes were examined at Kanazawa Medical University Hospital or Yayoi Hospital. The radius of the corneal curvature, the corneal thickness, anterior chamber depth, whole lens thickness, anterior chamber angle and the scattering light intensity were all observed on a slit section of the lens, and the intrapupillary area of the cataractous shadow was measured from a retroillumination image. The measurements were made twice at an interval of 14.2 days. There were no significant differences between the data of the 1st and 2nd examination in either place.

Entities:  

Mesh:

Year:  1992        PMID: 1484676     DOI: 10.1159/000267202

Source DB:  PubMed          Journal:  Ophthalmic Res        ISSN: 0030-3747            Impact factor:   2.892


  5 in total

1.  Quantitative evaluation of light scattering intensities of the crystalline lens for radiation related minimal change in interventional radiologists: a cross-sectional pilot study.

Authors:  Toshi Abe; Shigeru Furui; Hiroshi Sasaki; Yasuo Sakamoto; Shigeru Suzuki; Tatsuya Ishitake; Kinuyo Terasaki; Hiroshi Kohtake; Alexander M Norbash; Richard H Behrman; Naofumi Hayabuchi
Journal:  J Radiat Res       Date:  2012-11-09       Impact factor: 2.724

2.  Comparative evaluation of modified crater (endonucleation) chop and conventional crater chop techniques during phacoemulsification of hard nuclear cataracts: A randomized study.

Authors:  Sukriti Upadhyay; Pankaj Sharma; Jugal Kishore Chouhan; Rajesh Goyal
Journal:  Indian J Ophthalmol       Date:  2022-03       Impact factor: 2.969

3.  Determination of the density of human nuclear cataract lenses.

Authors:  Ke Xu; Yansheng Hao
Journal:  Mol Med Rep       Date:  2013-09-09       Impact factor: 2.952

4.  Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

Authors:  Xuhua Tan; Haotian Lin; Zhuoling Lin; Jingjing Chen; Xiangchen Tang; Lixia Luo; Weirong Chen; Yizhi Liu
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

5.  In vivo human crystalline lens topography.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Enrique Gambra; Alberto de Castro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2012-09-12       Impact factor: 3.732

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.