Literature DB >> 1477318

A multivariate analysis of mortality and hospital admissions with high-flux dialysis.

J C Hornberger1, M Chernew, J Petersen, A M Garber.   

Abstract

The use of high-flux dialysis in clinical practice increased rapidly despite an absence of reports on the clinical effectiveness of the technique. Mortality and hospital admission rates of patients treated with high-flux dialysis were evaluated and compared with those of patients treated with conventional dialysis in a hospital-based renal dialysis unit in northern California. By use of a retrospective, cross-over design, 253 patients enrolled in the dialysis unit from January 1987 to January 1991 were studied. During this period, 107 patients were treated with high-flux dialysis for at least 1 month, and all but 17 of them had received conventional dialysis before switching to high-flux dialysis. The remaining 146 patients were treated with only conventional dialysis. Of the 80 patients who died during the study period, 69 were receiving conventional dialysis and 11 were receiving high-flux dialysis. The multivariate analyses, adjusted for age, gender, ethnic background, type of renal failure, comorbid conditions, and duration of ESRD, showed that annual mortality was substantially less for patients treated with high-flux dialysis compared with that for patients treated with conventional dialysis (7 versus 20%; P < 0.001). The difference in the rate of hospital admissions was not statistically significant. In this nonexperimental study, methods were applied to control for selectivity bias and other factors that might confound the apparent treatment effect. The findings suggest that the potential benefits of high-flux dialysis are sufficient to justify further confirmation in a randomized, controlled trial.

Entities:  

Mesh:

Year:  1992        PMID: 1477318     DOI: 10.1681/ASN.V361227

Source DB:  PubMed          Journal:  J Am Soc Nephrol        ISSN: 1046-6673            Impact factor:   10.121


  10 in total

1.  Hemofiltration and hemodiafiltration reduce intradialytic hypotension in ESRD.

Authors:  Francesco Locatelli; Paolo Altieri; Simeone Andrulli; Piergiorgio Bolasco; Giovanna Sau; Luciano A Pedrini; Carlo Basile; Salvatore David; Mariano Feriani; Giovanni Montagna; Biagio Raffaele Di Iorio; Bruno Memoli; Raffaella Cravero; Giovanni Battaglia; Carmine Zoccali
Journal:  J Am Soc Nephrol       Date:  2010-09-02       Impact factor: 10.121

Review 2.  High-flux versus low-flux membranes for end-stage kidney disease.

Authors:  Suetonia C Palmer; Kannaiyan S Rabindranath; Jonathan C Craig; Paul J Roderick; Francesco Locatelli; Giovanni F M Strippoli
Journal:  Cochrane Database Syst Rev       Date:  2012-09-12

3.  Effect of membrane permeability on survival of hemodialysis patients.

Authors:  Francesco Locatelli; Alejandro Martin-Malo; Thierry Hannedouche; Alfredo Loureiro; Menelaos Papadimitriou; Volker Wizemann; Stefan H Jacobson; Stanislaw Czekalski; Claudio Ronco; Raymond Vanholder
Journal:  J Am Soc Nephrol       Date:  2008-12-17       Impact factor: 10.121

4.  Dialyzer Reuse and Outcomes of High Flux Dialysis.

Authors:  Christos Argyropoulos; Maria-Eleni Roumelioti; Abdus Sattar; John A Kellum; Lisa Weissfeld; Mark L Unruh
Journal:  PLoS One       Date:  2015-06-09       Impact factor: 3.240

5.  Comparison of the impact of high-flux dialysis on mortality in hemodialysis patients with and without residual renal function.

Authors:  Hyung Wook Kim; Su-Hyun Kim; Young Ok Kim; Dong Chan Jin; Ho Chul Song; Euy Jin Choi; Yong-Lim Kim; Yon-Su Kim; Shin-Wook Kang; Nam-Ho Kim; Chul Woo Yang; Yong Kyun Kim
Journal:  PLoS One       Date:  2014-06-06       Impact factor: 3.240

6.  The impact of high-flux dialysis on mortality rates in incident and prevalent hemodialysis patients.

Authors:  Hyung Wook Kim; Su-Hyun Kim; Young Ok Kim; Dong Chan Jin; Ho Chul Song; Euy Jin Choi; Yong-Lim Kim; Yon-Su Kim; Shin-Wook Kang; Nam-Ho Kim; Chul Woo Yang; Yong Kyun Kim
Journal:  Korean J Intern Med       Date:  2014-10-31       Impact factor: 2.884

7.  Association of intradialytic hypotension and convective volume in hemodiafiltration: results from a retrospective cohort study.

Authors:  Franklin G Mora-Bravo; Guadalupe De-La-Cruz; Sonia Rivera; Alfonso Mariscal Ramírez; Jochen G Raimann; Héctor Pérez-Grovas
Journal:  BMC Nephrol       Date:  2012-09-10       Impact factor: 2.388

8.  Effects of high versus low flux membranes on o2 saturation in hemodialysis patients.

Authors:  Ali Momeni; Hamid Rouhi; Masoud Amiri
Journal:  Nephrourol Mon       Date:  2012-12-15

9.  Effects of High-Flux versus Low-Flux Membranes on Pulmonary Function Tests in Hemodialysis Patients.

Authors:  Ali Momeni; Hamid Rouhi; Glareh Kiani; Masoud Amiri
Journal:  Tanaffos       Date:  2013

10.  Effect of different synthetic membranes on laboratory parameters and survival in chronic haemodialysis patients.

Authors:  Wilhelm Kreusser; Stefanie Reiermann; Gert Vogelbusch; Josè Bartual; Eckhard Schulze-Lohoff
Journal:  NDT Plus       Date:  2010-05
  10 in total