Vascular responses at proximal and distal edges of paclitaxel-eluting stents: serial intravascular ultrasound analysis from the TAXUS II trial.

Patrick W Serruys1, Muzaffer Degertekin, Kengo Tanabe, Mary E Russell, Giulio Guagliumi, John Webb, Jaap Hamburger, Wolfgang Rutsch, Christoph Kaiser, Robert Whitbourn, Edoardo Camenzind, Ian Meredith, François Reeves, Christoph Nienaber, Edouard Benit, Clemens Disco, Jörg Koglin, Antonio Colombo.   

Abstract

BACKGROUND: On the basis of brachytherapy experience, edge stenosis has been raised as a potential limitation for drug-eluting stents. We used serial intravascular ultrasound (IVUS) to prospectively analyze vessel responses in adjacent reference segments after implantation of polymer-controlled paclitaxel-eluting stents. METHODS AND
RESULTS: TAXUS II was a randomized, double-blind trial with 2 consecutive patient cohorts that compared slow-release (SR) and moderate-release (MR) paclitaxel-eluting stents with control bare metal stents (BMS). By protocol, all patients had postprocedure and 6-month follow-up IVUS. Quantitative IVUS analysis was performed by an independent core laboratory, blinded to treatment allocation, in 5-mm vessel segments immediately proximal and distal to the stent. Serial IVUS was available for 106 SR, 107 MR, and 214 BMS patients. For all 3 groups, a significant decrease in proximal-edge lumen area was observed at 6 months. The decrease was comparable (by ANOVA, P=0.194) for patients in the SR (-0.54+/-2.1 mm2) and MR (-0.88+/-1.9 mm2) groups compared with the BMS (-1.02+/-1.9 mm2) group. For the distal edge, a significant decrease in lumen area was only observed with BMS (-0.91+/-2.0 mm2, P<0.0001); this decrease was significantly attenuated with SR (0.08+/-2.0 mm2) and MR (-0.19+/-1.7 mm2) stents (P<0.0001 by ANOVA). Negative vessel remodeling was observed at the proximal (-0.48+/-2.2 mm2, P=0.011) but not the distal edges of BMS and at neither edge of SR or MR stents.
CONCLUSIONS: The marked reduction in in-stent restenosis with SR or MR stents is not associated with increased edge stenosis at 6-month follow-up IVUS. In fact, compared with BMS, there is instead a significant reduction in late lumen loss at the distal edge with TAXUS stents.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14769685     DOI: 10.1161/01.CIR.0000112566.87022.32

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  13 in total

1.  A finite element study on variations in mass transport in stented porcine coronary arteries based on location in the coronary arterial tree.

Authors:  Joseph T Keyes; Bruce R Simon; Jonathan P Vande Geest
Journal:  J Biomech Eng       Date:  2013-06       Impact factor: 2.097

Review 2.  Assessment of drug-eluting stents and bioresorbable stents by grayscale IVUS and IVUS-based imaging modalities.

Authors:  Salvatore Brugaletta; Jose Ribamar Costa; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

3.  Comparison of 16-slice computed tomography with conventional angiography to evaluate coronary artery stent patency.

Authors:  Irmak Durur-Subasi; Mecit Kantarci; Afak Durur-Karakaya; Adnan Okur
Journal:  Eurasian J Med       Date:  2009-04

4.  Plaque modification and stabilization after paclitaxel-coated balloon treatment for de novo coronary lesions.

Authors:  Ae-Young Her; Eun-Seok Shin; Ju-Hyun Chung; Yong Hoon Kim; Scot Garg; Joo Myung Lee; Joon-Hyung Doh; Chang-Wook Nam; Bon-Kwon Koo
Journal:  Heart Vessels       Date:  2019-01-30       Impact factor: 2.037

5.  Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

Authors:  Joelle M Kefer; Emmanuel Coche; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

Review 6.  Efficacy of drug eluting stents in patients with and without diabetes mellitus: indirect comparison of controlled trials.

Authors:  C Stettler; S Allemann; M Egger; S Windecker; B Meier; P Diem
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

7.  Location-dependent coronary artery diffusive and convective mass transport properties of a lipophilic drug surrogate measured using nonlinear microscopy.

Authors:  Joseph T Keyes; Bruce R Simon; Jonathan P Vande Geest
Journal:  Pharm Res       Date:  2012-12-07       Impact factor: 4.200

8.  Usual dose of simvastatin does not inhibit plaque progression and lumen loss at the peri-stent reference segments after bare-metal stent implantation: a serial intravascular ultrasound analysis.

Authors:  Young Joon Hong; Myung Ho Jeong; Yun Ha Choi; Eun Hye Ma; Jum Suk Ko; Min Goo Lee; Keun Ho Park; Doo Sun Sim; Nam Sik Yoon; Hyun Ju Youn; Kye Hun Kim; Hyung Wook Park; Ju Han Kim; Youngkeun Ahn; Jeong Gwan Cho; Jong Chun Park; Jung Chaee Kang
Journal:  Korean J Intern Med       Date:  2010-11-27       Impact factor: 3.165

9.  Resolution of late sirolimus-eluting stent thrombosis after tirofiban treatment.

Authors:  Ozlem Karakurt; Goksel Cagirci; Harun Kilic; Ramazan Akdemir
Journal:  Heart Vessels       Date:  2009-09-27       Impact factor: 2.037

10.  Deformationally dependent fluid transport properties of porcine coronary arteries based on location in the coronary vasculature.

Authors:  Joseph T Keyes; Danielle R Lockwood; Bruce R Simon; Jonathan P Vande Geest
Journal:  J Mech Behav Biomed Mater       Date:  2012-10-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.