Literature DB >> 14762647

Air sampling of organophosphate triesters using SPME under non-equilibrium conditions.

Sindra Isetun1, Ulrika Nilsson, Anders Colmsjö, Rolf Johansson.   

Abstract

Solid phase micro-extraction (SPME) was used to collect air samples of semi-volatile organophosphate triesters, a group of compounds that are commonly used as flame retardants/plasticisers and have therefore become ubiquitous indoor air pollutants. SPME is a simple sampling technique with several major advantages, including time-efficiency and low solvent consumption. Analyte losses also tend to be relatively low. In quantitative SPME, measurements are normally taken after the analyte has reached partitioning equilibrium between the fibre and the sample matrix. However, equilibrium sampling of semi-volatile compounds in air with SPME often takes several hours. Clearly, time-weighted average (TWA) sampling using SPME under non-equilibrium conditions could be considerably faster. So, in this study, the possibility of sampling organophosphate triesters under non-equilibrium conditions was tested. The most important variables proved to be the fibre coating and the air velocity during sampling. The highest uptake rate was obtained with polydimethylsiloxane (PDMS, 100 microm). The rate for this fibre was 150-fold higher than obtained with PDMS/DVB and Carbowax/DVB, both 65 microm. Contrary to theoretical expectations, the uptake rate appeared to be constant for all tested air velocities over the fibre surface >7 cm/s. These findings suggest that the uptake rate for non-equilibrium SPME sampling is independent of the sampling flow above this flow rate, which would considerably enhance the robustness and flexibility of the method. Applying this method for TWA sampling, with sampling periods of 1 h, detection limits lower than 2 ng/m(3) for individual organophosphate esters were obtained.

Entities:  

Year:  2004        PMID: 14762647     DOI: 10.1007/s00216-003-2489-6

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Field application of SPME as a novel tool for occupational exposure assessment with inhalational anesthetics.

Authors:  Mohammad Javad Zare Sakhvidi; AbdulRahman Bahrami; Alireza Ghiasvand; Hossein Mahjub; Ludovic Tuduri
Journal:  Environ Monit Assess       Date:  2011-11-18       Impact factor: 2.513

2.  Determination of the volatile fraction of phosphorus flame retardants in cushioning foam of upholstered furniture: towards respiratory exposure assessment.

Authors:  Mylène Ghislain; Joana Beigbeder; Loïc Dumazert; José-Marie Lopez-Cuesta; Mohammed Lounis; Stéphane Leconte; Valérie Desauziers
Journal:  Environ Monit Assess       Date:  2016-09-20       Impact factor: 2.513

3.  Application of portable gas chromatography-photo ionization detector combined with headspace sampling for field analysis of benzene, toluene, ethylbenzene, and xylene in soils.

Authors:  You-Ya Zhou; Ji-Fang Yu; Zeng-Guang Yan; Chao-Yan Zhang; Ya-Bo Xie; Li-Qiang Ma; Qing-Bao Gu; Fa-Sheng Li
Journal:  Environ Monit Assess       Date:  2012-07-27       Impact factor: 2.513

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.