Literature DB >> 14756178

Experimental and computational determination of neutron dose equivalent around radiotherapy accelerators.

E J Waller1, T J Jamieson, D Cole, T Cousins, R B Jammal.   

Abstract

An experimental and computational investigation of the neutron dose equivalent in the treatment room and maze of various radiotherapy accelerators in Canada was completed. A bubble detector was selected for the bulk of the measurements due to its relative insensitivity to gamma radiation. The rooms and accelerator heads were modelled using the MCNP4B Monte Carlo radiation transport code, modified with a photoneutron patch. The results of the investigation showed generally good agreement between the experiments. Monte Carlo and analytical approximations to the neutron dose equivalent, and suggest that if the analytical approximations are used carefully they may be substituted for more costly experimental or Monte Carlo determinations.

Mesh:

Year:  2003        PMID: 14756178     DOI: 10.1093/oxfordjournals.rpd.a006394

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  6 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Monte Carlo characterizations mapping of the (γ,n) and (n,γ) photonuclear reactions in the high energy X-ray radiation therapy.

Authors:  Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-31

3.  Safe bunker designing for the 18 MV Varian 2100 Clinac: a comparison between Monte Carlo simulation based upon data and new protocol recommendations.

Authors:  Manije Beigi; Fatemeh Afarande; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2015-11-17

4.  MC safe bunker designing for an 18 MV linac with nanoparticles included primary barriers and effect of the nanoparticles on the shielding aspects.

Authors:  Amir Ghasemi-Jangjoo; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-06

5.  Photo neutron dose equivalent rate in 15 MV X-ray beam from a Siemens Primus Linac.

Authors:  A Ghasemi; T Allahverdi Pourfallah; M R Akbari; H Babapour; M Shahidi
Journal:  J Med Phys       Date:  2015 Apr-Jun

6.  Calculation of Photoneutron Contamination of Varian Linac in ICRU Soft-Tissue Phantom Using MCNPX Code.

Authors:  Mojtaba Cheraghian; Tayyeb Pourfallah; Amir Abbas Sabouri-Dodaran; Mehrdad Gholami
Journal:  J Med Phys       Date:  2021-08-07
  6 in total