Literature DB >> 14755662

Pulse sequence for multislice T1rho-weighted MRI.

Andrew J Wheaton1, Arijitt Borthakur, Sridhar R Charagundla, Ravinder Reddy.   

Abstract

A 2D multislice spin-lock (MS-SL) MR pulse sequence is presented for rapid volumetric T1rho-weighted imaging. Image quality is compared with T1rho-weighted data collected using a single-slice (SS) SL sequence and T2-weighted data from a standard MS spin-echo (SE) sequence. Saturation of longitudinal magnetization by the application of nonselective SL pulses is experimentally measured and theoretically modeled as T2rho decay. The saturation data is used to correct the image data as a function of the SL pulse duration to make quantitative measurements of T1rho. Measurements of T1rho using the saturation-corrected MS-SL data are nearly identical to those measured using an SS-SL sequence. The MS-SL sequence produces quantitative T1rho maps of an entire sample volume with the high-SNR advantages conferred by SE-based sequences. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 14755662     DOI: 10.1002/mrm.10705

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Combined off-resonance imaging and T2 relaxation in the rotating frame for positive contrast MR imaging of infection in a murine burn model.

Authors:  Ovidiu C Andronesi; Dionyssios Mintzopoulos; Valeria Righi; Nikolaos Psychogios; Meenu Kesarwani; Jianxin He; Shingo Yasuhara; George Dai; Laurence G Rahme; Aria A Tzika
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

2.  T1rho contrast in functional magnetic resonance imaging.

Authors:  Justin Hulvershorn; Arijitt Borthakur; Luke Bloy; Eugene E Gualtieri; Ravinder Reddy; John S Leigh; Mark A Elliott
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

3.  Stimulus-induced Rotary Saturation (SIRS): a potential method for the detection of neuronal currents with MRI.

Authors:  Thomas Witzel; Fa-Hsuan Lin; Bruce R Rosen; Lawrence L Wald
Journal:  Neuroimage       Date:  2008-05-20       Impact factor: 6.556

4.  Characterizing breast cancer mouse xenografts with T₁ρ -MRI: a preliminary study.

Authors:  Lin Z Li; He N Xu; Ravinder Reddy
Journal:  Adv Exp Med Biol       Date:  2011       Impact factor: 2.622

5.  Lumbar intervertebral discs T2 relaxometry and T1ρ relaxometry correlation with age in asymptomatic young adults.

Authors:  Rafael Menezes-Reis; Carlos E Garrido Salmon; Gustavo P Bonugli; Debora Mazoroski; Mauricio H Tamashiro; Leonor G Savarese; Marcello Henrique Nogueira-Barbosa
Journal:  Quant Imaging Med Surg       Date:  2016-08

6.  In vivo measurement of plaque burden in a mouse model of Alzheimer's disease.

Authors:  Arijitt Borthakur; Tamar Gur; Andrew J Wheaton; Matthew Corbo; John Q Trojanowski; Virginia M-Y Lee; Ravinder Reddy
Journal:  J Magn Reson Imaging       Date:  2006-11       Impact factor: 4.813

Review 7.  Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage.

Authors:  Arijitt Borthakur; Eric Mellon; Sampreet Niyogi; Walter Witschey; J Bruce Kneeland; Ravinder Reddy
Journal:  NMR Biomed       Date:  2006-11       Impact factor: 4.044

8.  Correlating tissue outcome with quantitative multiparametric MRI of acute cerebral ischemia in rats.

Authors:  Kimmo T Jokivarsi; Yrjö Hiltunen; Pasi I Tuunanen; Risto A Kauppinen; Olli H J Gröhn
Journal:  J Cereb Blood Flow Metab       Date:  2009-11-11       Impact factor: 6.200

Review 9.  Novel contrast mechanisms at 3 Tesla and 7 Tesla.

Authors:  Ravinder R Regatte; Mark E Schweitzer
Journal:  Semin Musculoskelet Radiol       Date:  2008-10-10       Impact factor: 1.777

10.  Rapid acquisition strategy for functional T1ρ mapping of the brain.

Authors:  Casey P Johnson; Hye-Young Heo; Daniel R Thedens; John A Wemmie; Vincent A Magnotta
Journal:  Magn Reson Imaging       Date:  2014-08-02       Impact factor: 2.546

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.