Literature DB >> 14751575

Analysis of the influence of image resolution on the discriminating power of trabecular bone architectural parameters.

Zbislaw Tabor1.   

Abstract

In the study the influence of image resolution on the discriminating power of different parameters quantifying the architecture of trabecular bone is investigated. High-resolution images of 200-microm-thick sections of young and old trabecular bone are collected. Different architectural parameters are evaluated and shown to be statistically different in both groups of images. Then the resolution of the images is artificially degraded to the level comparable with resolution achievable in vivo. It is shown that although the errors of evaluation are quite large for low-resolution images, the statistical difference present in the original data is still observed for parameters that depend only on the global characteristics of trabecular structure or marrow space, or depend only linearly on the number and area of disconnected parts of marrow space or trabecular structure. The parameters that fulfill such conditions are Euler number, mean area of marrow cavities, star volume and trabecular spacing. The statistical difference disappears for parameters that depend on the number and area of disconnected parts of marrow space or trabecular structure in a nonlinear manner, that is, marrow and trabecular disconnection probabilities, two-point distance and second moment of marrow cavities area distribution. It is shown that the mechanism that leads to the losing of discriminating power does not depend crucially on the estimation error or noise level. This mechanism, which involves an interplay between changes of mean values and standard deviations, is the manifestation of partial volume effect amplified with image segmentation.

Mesh:

Year:  2004        PMID: 14751575     DOI: 10.1016/j.bone.2003.10.002

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  6 in total

1.  Optimal sample volumes of human trabecular bone in μCT analysis within vertebral body and femoral head.

Authors:  Xin-Xin Wen; Chun-Lin Zong; Chao Xu; Xiang-Yu Ma; Fa-Qi Wang; Ya-Fei Feng; Ya-Bo Yan; Wei Lei
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  Resolution dependence of the non-metric trabecular structure indices.

Authors:  Miki Sode; Andrew J Burghardt; Robert A Nissenson; Sharmila Majumdar
Journal:  Bone       Date:  2007-12-23       Impact factor: 4.398

Review 3.  New laboratory tools in the assessment of bone quality.

Authors:  D Chappard; M F Baslé; E Legrand; M Audran
Journal:  Osteoporos Int       Date:  2011-02-24       Impact factor: 4.507

4.  Influence of Metastatic Bone Lesion Type and Tumor Origin on Human Vertebral Bone Architecture, Matrix Quality, and Mechanical Properties.

Authors:  Stacyann Bailey; Marc A Stadelmann; Philippe K Zysset; Deepak Vashishth; Ron N Alkalay
Journal:  J Bone Miner Res       Date:  2022-04-05       Impact factor: 6.390

5.  Influence of spatial camera resolution in high-speed videoendoscopy on laryngeal parameters.

Authors:  Patrick Schlegel; Melda Kunduk; Michael Stingl; Marion Semmler; Michael Döllinger; Christopher Bohr; Anne Schützenberger
Journal:  PLoS One       Date:  2019-04-22       Impact factor: 3.240

6.  Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep.

Authors:  Aso Muhammad Ali Muhammad; Norliza Ibrahim; Rohana Ahmad; Muhammad Khan Asif; Zamri Radzi; Zuraiza Mohamad Zaini; Hairil Rashmizal Abdul Razak
Journal:  BMC Oral Health       Date:  2020-02-10       Impact factor: 2.757

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.