Accuracy of peripheral quantitative computed tomography (pQCT) for assessing area and density of mouse cortical bone.

M D Brodt1, G B Pelz, J Taniguchi, M J Silva.   

Abstract

Peripheral quantitative computed tomography (pQCT) is increasingly used for measurement of cortical bone geometry and density in mice. We evaluated the accuracy of pQCT for area and density measurements of thin-walled aluminum phantoms and mouse femora. Aluminum tubes with varying wall thicknesses and femora from 1- to 6-month-old C3H/HeJ (C3H) and C57B1/6J (B6) mice (average cortical thickness 0.14-0.29 mm) were scanned at 70- or 90-microm resolution. pQCT values of area were compared to optical values determined after sectioning, while pQCT density (vBMD) was compared to solid aluminum density or correlated to bone ash content. For the aluminum phantoms, the error in pQCT area and density depended strongly on wall thickness, and density was consistently underestimated. For mouse femora, threshold values were found that produced zero error in bone area for each strain and age group, although the optimal threshold differed between groups. pQCT vBMD correlated strongly with ash content (r2=0.7), although the regression equations differed between strains and the magnitude of the inter-strain difference in vBMD was fourfold greater than the difference in ash content. This finding suggests that pQCT can overestimate the differences in volumetric mineral density between inbred mouse strains whose bones are of different thickness (e.g., C3H vs. B6). In conclusion, both area and density values obtained by pQCT depend strongly on specimen thickness, consistent with a partial volume averaging artifact. Investigators using pQCT to assess cortical bones in mice should be aware of the potential for cortical thickness-dependent errors.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14743831     DOI: 10.1007/s00223-002-0006-0

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  6 in total

1.  Exercise-induced changes in the cortical bone of growing mice are bone- and gender-specific.

Authors:  Joseph M Wallace; Rupak M Rajachar; Matthew R Allen; Susan A Bloomfield; Pamela G Robey; Marian F Young; David H Kohn
Journal:  Bone       Date:  2007-01-19       Impact factor: 4.398

Review 2.  Genetics of aging bone.

Authors:  Douglas J Adams; David W Rowe; Cheryl L Ackert-Bicknell
Journal:  Mamm Genome       Date:  2016-06-06       Impact factor: 2.957

3.  Dual-energy X-ray absorptiometry, peripheral quantitative computed tomography, and micro-computed tomography techniques are discordant for bone density and geometry measurements in the guinea pig.

Authors:  Ivy L Mak; Jason R DeGuire; Paula Lavery; Sherry Agellon; Hope A Weiler
Journal:  J Bone Miner Metab       Date:  2015-06-10       Impact factor: 2.626

4.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

5.  Inhibition of vascular endothelial growth factor in young adult mice causes low bone blood flow and bone strength with no effect on bone mass in trabecular regions.

Authors:  N E Lane; J S Nyman; S Uppuganti; A J Chaudhari; J I Aguirre; K Shidara; X P Liu; W Yao; D B Kimmel
Journal:  Bone Rep       Date:  2019-05-11

Review 6.  Bone Phenotyping Approaches in Human, Mice and Zebrafish - Expert Overview of the EU Cost Action GEMSTONE ("GEnomics of MusculoSkeletal traits TranslatiOnal NEtwork").

Authors:  Ines Foessl; J H Duncan Bassett; Åshild Bjørnerem; Björn Busse; Ângelo Calado; Pascale Chavassieux; Maria Christou; Eleni Douni; Imke A K Fiedler; João Eurico Fonseca; Eva Hassler; Wolfgang Högler; Erika Kague; David Karasik; Patricia Khashayar; Bente L Langdahl; Victoria D Leitch; Philippe Lopes; Georgios Markozannes; Fiona E A McGuigan; Carolina Medina-Gomez; Evangelia Ntzani; Ling Oei; Claes Ohlsson; Pawel Szulc; Jonathan H Tobias; Katerina Trajanoska; Şansın Tuzun; Amina Valjevac; Bert van Rietbergen; Graham R Williams; Tatjana Zekic; Fernando Rivadeneira; Barbara Obermayer-Pietsch
Journal:  Front Endocrinol (Lausanne)       Date:  2021-12-01       Impact factor: 5.555

  6 in total