Literature DB >> 14739307

Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: development and initial evaluation.

Daniel Kim1, Wesley D Gilson, Christopher M Kramer, Frederick H Epstein.   

Abstract

A breath-hold two-dimensional cine magnetic resonance (MR) pulse sequence based on displacement encoding with stimulated echoes (DENSE) for quantitative myocardial motion tracking was developed and evaluated. In the sequence, complementary spatial modulation of magnetization was used for time-independent artifact suppression, and echo-planar imaging was used for rapid data sampling. Twelve healthy volunteers underwent cine DENSE MR imaging, and six of them also underwent conventional MR imaging myocardial tagging. The circumferential shortening component of strain (E(cc)) was measured on cine DENSE MR images and conventional tagged MR images. With complementary spatial modulation of magnetization, 10% or less of the total cine DENSE MR image energy was attributed to an artifact-generating echo during systolic imaging. Two-dimensional intramyocardial displacement and strain were measured at cine DENSE MR imaging with spatial resolution and temporal resolution of 2.7 x 2.7 mm and 60 msec, respectively. E(cc) measured at cine DENSE MR imaging correlated well with that measured at conventional MR imaging tagging (slope = 0.88, intercept = 0.00, R = 0.87). Copyright RSNA, 2004

Mesh:

Year:  2004        PMID: 14739307     DOI: 10.1148/radiol.2303021213

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  113 in total

Review 1.  Multi-modality imaging of diastolic function.

Authors:  Michael Salerno
Journal:  J Nucl Cardiol       Date:  2010-04       Impact factor: 5.952

2.  Monocyte and/or macrophage infiltration of heart after myocardial infarction: MR imaging by using T1-shortening liposomes.

Authors:  Nivedita K Naresh; Yaqin Xu; Alexander L Klibanov; Moriel H Vandsburger; Craig H Meyer; Jonathan Leor; Christopher M Kramer; Brent A French; Frederick H Epstein
Journal:  Radiology       Date:  2012-06-21       Impact factor: 11.105

Review 3.  Cardiovascular magnetic resonance: structure, function, perfusion, and viability.

Authors:  David C Isbell; Christopher M Kramer
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

Review 4.  MRI of left ventricular function.

Authors:  Frederick H Epstein
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

5.  Balanced multipoint displacement encoding for DENSE MRI.

Authors:  Xiaodong Zhong; Patrick A Helm; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

6.  Reconstruction of myocardial tissue motion and strain fields from displacement-encoded MR imaging.

Authors:  Yi Liu; Han Wen; Robert C Gorman; James J Pilla; Joseph H Gorman; Gerald Buckberg; Shawn D Teague; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-06-26       Impact factor: 4.733

7.  Cardiac motion recovery via active trajectory field models.

Authors:  Andrew D Gilliam; Frederick H Epstein; Scott T Acton
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-01-20

8.  Impact of mechanical activation, scar, and electrical timing on cardiac resynchronization therapy response and clinical outcomes.

Authors:  Kenneth C Bilchick; Sujith Kuruvilla; Yasmin S Hamirani; Raghav Ramachandran; Samantha A Clarke; Katherine M Parker; George J Stukenborg; Pamela Mason; John D Ferguson; J Randall Moorman; Rohit Malhotra; J Michael Mangrum; Andrew E Darby; John Dimarco; Jeffrey W Holmes; Michael Salerno; Christopher M Kramer; Frederick H Epstein
Journal:  J Am Coll Cardiol       Date:  2014-03-05       Impact factor: 24.094

9.  Accurate high-resolution measurements of 3-D tissue dynamics with registration-enhanced displacement encoded MRI.

Authors:  Arnold D Gomez; Samer S Merchant; Edward W Hsu
Journal:  IEEE Trans Med Imaging       Date:  2014-03-14       Impact factor: 10.048

10.  Reproducibility of cine displacement encoding with stimulated echoes (DENSE) in human subjects.

Authors:  Kai Lin; Leng Meng; Jeremy D Collins; Varun Chowdhary; Michael Markl; James C Carr
Journal:  Magn Reson Imaging       Date:  2016-08-26       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.