Literature DB >> 14738195

Robin Heart 2003--present state of the Polish telemanipulator project for cardiac surgery assistance.

Z Nawrat1, L Podsedkowski, K Mianowski, P Wróblewski, P Kostka, R Pruski, Z Małota, Z Religa.   

Abstract

The Polish telemanipulator (Robin Heart), for use in cardiac surgery, has been realized by the Foundation of Cardiac Surgery Development in Zabrze, Poland, in cooperation with specialists from the Technical University of Lodz and Warsaw University of Technology. The brief history of robotic surgery and fundamental advantages of employing robots in this field--safe, reliable and repeatable operative results with less patient pain, trauma and recovery time--follow the assumptions of the Polish Cardio-Robot project. The cardiac surgery robot, Robin Heart, is an original construction with a segment type structure which allows the various combination of its parts for different types of surgery. The telemanipulator for cardiac surgery will consist of two arms equipped with tools and one arm holding the camera. Several models suitable for surgeon contact systems, using the experience of centers designing the artificial hand and haptic systems have been worked out. The detailed mechanical analysis and original construction of main parts of the robot and development of the surgical planning system are presented in further sections.

Entities:  

Mesh:

Year:  2003        PMID: 14738195     DOI: 10.1177/039139880302601209

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  3 in total

Review 1.  Prevalence of haptic feedback in robot-mediated surgery: a systematic review of literature.

Authors:  Farshid Amirabdollahian; Salvatore Livatino; Behrad Vahedi; Radhika Gudipati; Patrick Sheen; Shan Gawrie-Mohan; Nikhil Vasdev
Journal:  J Robot Surg       Date:  2017-12-01

2.  Share control of surgery robot master manipulator guiding tool along the standard path.

Authors:  Lukasz Fracczak; Mateusz Szaniewski; Leszek Podsedkowski
Journal:  Int J Med Robot       Date:  2019-02-19       Impact factor: 2.547

3.  Are the surgeon's movements repeatable? An analysis of the feasibility and expediency of implementing support procedures guiding the surgical tools and increasing motion accuracy during the performance of stereotypical movements by the surgeon.

Authors:  Leszek Robert Podsędkowski; Jacek Moll; Maciej Moll; Łukasz Frącczak
Journal:  Kardiochir Torakochirurgia Pol       Date:  2014-03-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.