Literature DB >> 14735076

Ulnar nerve palsy at the elbow after surgical treatment for fractures of the olecranon.

Norio Ishigaki1, Shigeharu Uchiyama, Hiroyuki Nakagawa, Mikio Kamimura, Tadaatsu Miyasaka.   

Abstract

Despite close proximity of the fracture site to the nerve, ulnar nerve palsy after surgery for fracture of the olecranon is uncommon. We examined 18 cases of fracture of the olecranon treated surgically retrospectively to see if there were any characteristics common to 4 cases of ulnar nerve palsy. Three cases of palsy with a comminuted fracture had fair or poor reduction as revealed by both the lateral and anteroposterior radiographs taken at the time of surgery. The other case, with little displacement of the fragment, had osteoarthritic changes at the medial side of the elbow. The mechanism of development of ulnar nerve palsy is considered to be multifactorial. However, it should be noted that evaluation of reduction of the fracture, not only on a lateral radiograph but also on an anteroposterior radiograph at the time of surgery, is important to prevent the ulnar nerve from being jeopardized.

Entities:  

Mesh:

Year:  2004        PMID: 14735076     DOI: 10.1016/s1058-2746(03)00220-9

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  4 in total

1.  Factors Associated With Reoperation After Fixation of Displaced Olecranon Fractures.

Authors:  Femke M A P Claessen; Yvonne Braun; Rinne M Peters; George Dyer; Job N Doornberg; David Ring
Journal:  Clin Orthop Relat Res       Date:  2015-08-07       Impact factor: 4.176

2.  Olecranon fractures: factors influencing re-operation.

Authors:  Mark Christopher Snoddy; Maximilian Frank Lang; Thomas J An; Phillip Michael Mitchell; William Jeffrey Grantham; Benjamin Scoot Hooe; Harrison Ford Kay; Ritwik Bhatia; Rachel V Thakore; Jason Michael Evans; William Todd Obremskey; Manish Kumar Sethi
Journal:  Int Orthop       Date:  2014-06-04       Impact factor: 3.075

3.  Epidemiologic features and management of elbow dislocation with associated fracture in pediatric population.

Authors:  Xuemin Lu; Guisen Yan; Ming Lu; Yuan Guo
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

4.  A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures.

Authors:  Wulian Wang; Guangwen Wu; Fuer Shen; Yiyuan Zhang; Xianxiang Liu
Journal:  Exp Ther Med       Date:  2012-09-01       Impact factor: 2.447

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.