AIM: To establish a solid phase extraction-high performance liquid chromatographic (SPE-HPLC) method for determining plasma scutellarin concentration, and study its pharmacokinetics after i.v. breviscapine in rabbits. METHODS: Methanol-water-phosphoric acid (50:50:0.5) mixture was used as mobile phase, Nucleosil C18 column (250 mm x 4.6 mm ID) was selected. The wavelength of UV detection was 335 nm. Fifteen rabbits, randomized into 3 groups, were given breviscapine i.v. at the dose of 10, 20 and 40 mg.kg-1. Scutellarin in plasma was determined by SPE-HPLC method. RESULTS: Linearity was obtained over the range of 0.02-10.0 mg.L-1 of scutellarin. The method recovery was 96.15%-99.31%; the within-day and between-day RSDs were all below 10%. After i.v. 10, 20 and 40 mg.kg-1 of breviscapine to rabbits, the concentration-time curve of scutellarin fitted to a three compartment model. The main pharmacokinetic parameters showed no significant difference between low and medium doses, but the difference was significant between high dose and other doses. CONCLUSION: This assay method was accurate, sensitive, simple and suitable for the measurement of plasma scutellarin concentration. The pharmacokinetic characteristics were found to fit a three-compartment model following i.v. injection of breviscapine to rabbits. The changes of drug concentration in vivo exhibited linear kinetics ove the dosage range of 10-20 mg.kg-1, but when the dosage was 40 mg.kg-1, the linear kinetic properties disappeared.
AIM: To establish a solid phase extraction-high performance liquid chromatographic (SPE-HPLC) method for determining plasma scutellarin concentration, and study its pharmacokinetics after i.v. breviscapine in rabbits. METHODS:Methanol-water-phosphoric acid (50:50:0.5) mixture was used as mobile phase, Nucleosil C18 column (250 mm x 4.6 mm ID) was selected. The wavelength of UV detection was 335 nm. Fifteen rabbits, randomized into 3 groups, were given breviscapine i.v. at the dose of 10, 20 and 40 mg.kg-1. Scutellarin in plasma was determined by SPE-HPLC method. RESULTS: Linearity was obtained over the range of 0.02-10.0 mg.L-1 of scutellarin. The method recovery was 96.15%-99.31%; the within-day and between-day RSDs were all below 10%. After i.v. 10, 20 and 40 mg.kg-1 of breviscapine to rabbits, the concentration-time curve of scutellarin fitted to a three compartment model. The main pharmacokinetic parameters showed no significant difference between low and medium doses, but the difference was significant between high dose and other doses. CONCLUSION: This assay method was accurate, sensitive, simple and suitable for the measurement of plasma scutellarin concentration. The pharmacokinetic characteristics were found to fit a three-compartment model following i.v. injection of breviscapine to rabbits. The changes of drug concentration in vivo exhibited linear kinetics ove the dosage range of 10-20 mg.kg-1, but when the dosage was 40 mg.kg-1, the linear kinetic properties disappeared.