Literature DB >> 14727843

Next generation fluidized bed granulator automation.

J Rantanen1, M Känsäkoski, J Suhonen, J Tenhunen, S Lehtonen, T Rajalahti, J P Mannermaa, J Yliruusi.   

Abstract

A system for fluidized bed granulator automation with in-line multichannel near infrared (NIR) moisture measurement and a unique air flow rate measurement design was assembled, and the information gained was investigated. The multivariate process data collected was analyzed using principal component analysis (PCA). The test materials (theophylline and microcrystalline cellulose) were granulated and the calibration behavior of the multichannel NIR set-up was evaluated against full Fourier Transform (FT) NIR spectra. Accurate and reliable process air flow rate measurement proved critical in controlling the granulation process. The process data describing the state of the process was projected in two dimensions, and the information from various trend charts was outlined simultaneously. The absorbence of test material at correction wavelengths (NIR region) and the nature of material-water interactions affected the detected in-line NIR water signal. This resulted in different calibration models for the test materials. Development of process analytical methods together with new data visualization algorithms creates new tools for in-process control of the fluidized bed granulation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 14727843      PMCID: PMC2784821          DOI: 10.1208/pt010210

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  6 in total

1.  Use of the near-infrared reflectance method for measurement of moisture content during granulation.

Authors:  J Rantanen; O Antikainen; J P Mannermaa; J Yliruusi
Journal:  Pharm Dev Technol       Date:  2000       Impact factor: 3.133

2.  Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy. Part I. System development and control.

Authors:  P A Hailey; P Doherty; P Tapsell; T Oliver; P K Aldridge
Journal:  J Pharm Biomed Anal       Date:  1996-03       Impact factor: 3.935

3.  On-line monitoring of powder blend homogeneity by near-infrared spectroscopy.

Authors:  S S Sekulic; H W Ward; D R Brannegan; E D Stanley; C L Evans; S T Sciavolino; P A Hailey; P K Aldridge
Journal:  Anal Chem       Date:  1996-02-01       Impact factor: 6.986

4.  Near-infrared spectroscopic monitoring of the film coating process.

Authors:  J D Kirsch; J K Drennen
Journal:  Pharm Res       Date:  1996-02       Impact factor: 4.200

5.  Determination of film-coated tablet parameters by near-infrared spectroscopy.

Authors:  J D Kirsch; J K Drennen
Journal:  J Pharm Biomed Anal       Date:  1995-09       Impact factor: 3.935

6.  On-line moisture detection for a microwave vacuum dryer.

Authors:  J G White
Journal:  Pharm Res       Date:  1994-05       Impact factor: 4.200

  6 in total
  3 in total

1.  Characterization of particle sizes in bulk pharmaceutical solids using digital image information.

Authors:  Niklas Laitinen; Osmo Antikainen; Jouko Yliruusi
Journal:  AAPS PharmSciTech       Date:  2003-10-13       Impact factor: 3.246

2.  Particle size, moisture, and fluidization variations described by indirect in-line physical measurements of fluid bed granulation.

Authors:  Tanja Lipsanen; Tero Närvänen; Heikki Räikkönen; Osmo Antikainen; Jouko Yliruusi
Journal:  AAPS PharmSciTech       Date:  2008-10-17       Impact factor: 3.246

3.  Development of an automation system for a tablet coater.

Authors:  Mirja Ruotsalainen; Jyrki Heinämäki; Jukka Rantanen; Jouko Yliruusi
Journal:  AAPS PharmSciTech       Date:  2002       Impact factor: 3.246

  3 in total