BACKGROUND: Standard videoendoscopy identifies columnar-lined esophagus but cannot distinguish intestinal metaplasia from other types of epithelium. Enhanced-magnification endoscopy identifies different mucosal pit patterns. A preliminary study suggested that a type 3 pattern is associated with the presence of intestinal metaplasia. This study assesses the value of enhanced-magnification endoscopy for the detection of intestinal metaplasia in the distal esophagus and esophagogastric junction in patients undergoing diagnostic EGD. METHODS: Patients undergoing diagnostic endoscopy for upper-GI symptoms underwent enhanced-magnification endoscopy after instillation of 1.5% acetic acid. The enhanced-magnification endoscopy mucosal pattern was classified into 3 types: 1, normal pits; 2, slit-reticular pattern; and 3, gyrus-villous pattern. Preliminary studies indicated that the type 3 pattern was related to intestinal metaplasia. One to 6 biopsies were targeted to areas having a type 3 pattern in columnar-appearing mucosa in the distal esophagus or esophagogastric junction. In the absence of type 3 pattern, one to 8 biopsies were targeted to areas with a type 2 pattern in columnar-appearing mucosa in the distal esophagus or esophagogastric junction. RESULTS: The overall frequency of intestinal metaplasia in the esophagus and esophagogastric junction was 38.8% (26/67 patients). There was a good correlation between the type 3 pattern and intestinal metaplasia in targeted biopsy specimens (sensitivity 88.5%, specificity 90.2%, positive predictive value 85.2%, negative predictive value 92.5%, overall accuracy 90.0%). CONCLUSIONS: Enhanced-magnification endoscopy is useful for detection of intestinal metaplasia in distal esophagus and esophagogastric junction.
BACKGROUND: Standard videoendoscopy identifies columnar-lined esophagus but cannot distinguish intestinal metaplasia from other types of epithelium. Enhanced-magnification endoscopy identifies different mucosal pit patterns. A preliminary study suggested that a type 3 pattern is associated with the presence of intestinal metaplasia. This study assesses the value of enhanced-magnification endoscopy for the detection of intestinal metaplasia in the distal esophagus and esophagogastric junction in patients undergoing diagnostic EGD. METHODS:Patients undergoing diagnostic endoscopy for upper-GI symptoms underwent enhanced-magnification endoscopy after instillation of 1.5% acetic acid. The enhanced-magnification endoscopy mucosal pattern was classified into 3 types: 1, normal pits; 2, slit-reticular pattern; and 3, gyrus-villous pattern. Preliminary studies indicated that the type 3 pattern was related to intestinal metaplasia. One to 6 biopsies were targeted to areas having a type 3 pattern in columnar-appearing mucosa in the distal esophagus or esophagogastric junction. In the absence of type 3 pattern, one to 8 biopsies were targeted to areas with a type 2 pattern in columnar-appearing mucosa in the distal esophagus or esophagogastric junction. RESULTS: The overall frequency of intestinal metaplasia in the esophagus and esophagogastric junction was 38.8% (26/67 patients). There was a good correlation between the type 3 pattern and intestinal metaplasia in targeted biopsy specimens (sensitivity 88.5%, specificity 90.2%, positive predictive value 85.2%, negative predictive value 92.5%, overall accuracy 90.0%). CONCLUSIONS: Enhanced-magnification endoscopy is useful for detection of intestinal metaplasia in distal esophagus and esophagogastric junction.
Authors: Kenneth K Wang; Ngozi Okoro; Ganapathy Prasad; Michel WongKeeSong; Navtej S Buttar; Jianmin Tian Journal: Gastrointest Endosc Clin N Am Date: 2011-01
Authors: Alejandro Nieponice; Adolfo E Badaloni; Blair A Jobe; Toshitaka Hoppo; Carlos Pellegrini; Vic Velanovich; Gary W Falk; Kevin Reavis; Lee Swanstrom; Virender K Sharma; Fabio Nachman; Franco F Ciotola; Luis E Caro; Cecilio Cerisoli; Demetrio Cavadas; Luis Durand Figueroa; Daniel Pirchi; Michael Gibson; Santiago Elizalde; Henry Cohen Journal: World J Surg Date: 2014-01 Impact factor: 3.352