Literature DB >> 14716285

Arthroscopic biceps tenodesis using a bioabsorbable interference screw.

Ian K Y Lo1, Stephen S Burkhart.   

Abstract

Arthroscopic biceps tenodesis has rarely been reported. The purpose of this study is to present our technique of arthroscopic biceps tenodesis using the Bio-Tenodesis (Arthrex, Naples, FL) screw system. This system uses a uniquely designed screwdriver that allows manipulation of the biceps tendon subacromially and intra-articularly, facilitates placement and maintenance of the biceps tendon at the base of the bone socket during interference screw insertion, and assures an adequate bone-tendon-screw interface.

Entities:  

Mesh:

Year:  2004        PMID: 14716285     DOI: 10.1016/j.arthro.2003.11.017

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  29 in total

1.  The long head of biceps as a source of pain in active population: tenotomy or tenodesis? A comparison of 2 case series with isolated lesions.

Authors:  Giacomo Delle Rose; Mario Borroni; Alessandro Silvestro; Raffaele Garofalo; Marco Conti; Pasquale De Nittis; Alessandro Castagna
Journal:  Musculoskelet Surg       Date:  2012-04-18

2.  To detach the long head of the biceps tendon after tenodesis or not: outcome analysis at the 4-year follow-up of two different techniques.

Authors:  Francesco Franceschi; Umile Giuseppe Longo; Laura Ruzzini; Rocco Papalia; Giacomo Rizzello; Vincenzo Denaro
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

3.  Biomechanical characterization of unicortical button fixation: a novel technique for proximal subpectoral biceps tenodesis.

Authors:  Joseph P DeAngelis; Alvin Chen; Michael Wexler; Benjamin Hertz; Leandro Grimaldi Bournissaint; Ara Nazarian; Arun J Ramappa
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-20       Impact factor: 4.342

4.  Open reconstruction of the anterior glenohumeral capsulolabral structures with tendon allograft in chronic shoulder instability.

Authors:  S Braun; M P Horan; P J Millett
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

5.  Medial biceps sling takedown may be necessary to expose an occult subscapularis tendon tear.

Authors:  Robert U Hartzler; Stephen S Burkhart
Journal:  Arthrosc Tech       Date:  2014-12-15

6.  The low-anterolateral portal for arthroscopic biceps tenodesis: description of technique and cadaveric study.

Authors:  Michael L Knudsen; Jason C Hibbard; David J Nuckley; Jonathan P Braman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-12       Impact factor: 4.342

7.  Arthroscopic recognition and repair of the torn subscapularis tendon.

Authors:  Patrick J Denard; Stephen S Burkhart
Journal:  Arthrosc Tech       Date:  2013-10-07

8.  The biomechanical performance of a new forked knotless biceps tenodesis compared to a knotless and suture anchor tenodesis.

Authors:  Olaf Lorbach; Christian Trennheuser; Dieter Kohn; Konstantinos Anagnostakos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-08       Impact factor: 4.342

9.  Biceps tenodesis with interference screw: cyclic testing of different techniques.

Authors:  Onur Hapa; Cüneyd Günay; Erkam Kömürcü; Hüsamettin Cakıcı; Ergun Bozdağ
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-12       Impact factor: 4.342

Review 10.  Outcomes following long head of biceps tendon tenodesis.

Authors:  Saad M AlQahtani; Ryan T Bicknell
Journal:  Curr Rev Musculoskelet Med       Date:  2016-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.