Biceps tenodesis with interference screw: cyclic testing of different techniques.

Onur Hapa1, Cüneyd Günay, Erkam Kömürcü, Hüsamettin Cakıcı, Ergun Bozdağ.   

Abstract

Different surgical techniques exist for biceps tenodesis. The most secure fixation technique is with interference screws. The purpose of the study was to compare the biomechanical performance of three different interference screw biceps tenodesis fixation methods, which involve different tunnel preparation methods. Using a sheep shoulder model and metal interference screws, a bone wedge technique was compared to serial tunnel dilation and a control group. After a preload, all repairs were cyclically loaded (20-60 N) for 100 cycles followed by destructive testing. Biceps tenodesis using an interference screw--bone wedge technique showed statistically lower cyclic displacement (8.1 ± 6.4 mm) than serial dilatation with an interference screw (21.3 ± 8.4 mm) or interference screw fixation alone (18.3 ± 8.3 mm) (P = 0.02). There were no statistically significant differences in ultimate failure strength for any of the interference screw biceps tenodesis techniques tested. The tunnel preparation method chosen for interference screw fixed biceps tenodesis can have a positive effect on tenodesis performance. Using the bone wedge technique may allow a more rapid rehabilitation program applicable for the traumatic biceps tendon rupture seen in young, athletic patients with high demands.

Entities:  

Mesh:

Year:  2010        PMID: 20549186     DOI: 10.1007/s00167-010-1180-7

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  31 in total

1.  Bone mass in female cross-country skiers: relationship between muscle strength and different BMD sites.

Authors:  U Pettersson; H Alfredson; P Nordström; K Henriksson-Larsén; R Lorentzon
Journal:  Calcif Tissue Int       Date:  2000-09       Impact factor: 4.333

2.  Biceps rupture in body builders: three case reports of rupture of the long head of the biceps at the tendon-labrum junction.

Authors:  Marcus R Cope; Anil Ali; Neil C Bayliss
Journal:  J Shoulder Elbow Surg       Date:  2004 Sep-Oct       Impact factor: 3.019

3.  The biomechanical evaluation of four fixation techniques for proximal biceps tenodesis.

Authors:  Augustus D Mazzocca; James Bicos; Stephen Santangelo; Anthony A Romeo; Robert A Arciero
Journal:  Arthroscopy       Date:  2005-11       Impact factor: 4.772

4.  Effect of tibial tunnel dilation on pullout strength of semitendinosus-gracilis graft in anterior cruciate ligament reconstruction.

Authors:  E Lyle Cain; Barry B Phillips; Steven J Charlebois; Frederick M Azar
Journal:  Orthopedics       Date:  2005-08       Impact factor: 1.390

5.  Initial fixation strength of a new hybrid technique for femoral ACL graft fixation: the bone wedge technique.

Authors:  Mirco Herbort; Andre Weimann; Thore Zantop; Michael Strobel; Michael Raschke; Wolf Petersen
Journal:  Arch Orthop Trauma Surg       Date:  2006-08-26       Impact factor: 3.067

6.  Bioabsorbable screw divergence angle, not tunnel preparation method influences soft tissue tendon graft-bone tunnel fixation in healthy bone.

Authors:  Andrew R Duffee; Jeffrey A Brunelli; John Nyland; Robert Burden; Akbar Nawab; David Caborn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-09       Impact factor: 4.342

7.  Arthroscopic biceps tenodesis using interference screw: end-tunnel technique.

Authors:  Seung-Ho Kim; Jae Chul Yoo
Journal:  Arthroscopy       Date:  2005-11       Impact factor: 4.772

8.  The effect of bone compaction on early fixation of porous-coated implants.

Authors:  J R Green; J A Nemzek; S P Arnoczky; L L Johnson; M S Balas
Journal:  J Arthroplasty       Date:  1999-01       Impact factor: 4.757

9.  Time-dependent changes in failure loads of 3 biceps tenodesis techniques: in vivo study in a sheep model.

Authors:  Onder Kilicoglu; Ozgur Koyuncu; Mehmet Demirhan; Cem Zeki Esenyel; Ata Can Atalar; Serhat Ozsoy; Ergun Bozdag; Emin Sunbuloglu; Bilge Bilgic
Journal:  Am J Sports Med       Date:  2005-07-11       Impact factor: 6.202

10.  Comparison of direct and indirect interference screw fixation for tendon graft in rabbits.

Authors:  Tomohiro Tomihara; Hirotsugu Ohashi; Hirotake Yo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-02       Impact factor: 4.342

View more
  3 in total

Review 1.  Outcomes following long head of biceps tendon tenodesis.

Authors:  Saad M AlQahtani; Ryan T Bicknell
Journal:  Curr Rev Musculoskelet Med       Date:  2016-12

2.  Osteomyelitis: A Rare Complication After Subpectoral Biceps Tenodesis.

Authors:  Khang H Dang; Anil K Dutta
Journal:  Orthop J Sports Med       Date:  2019-01-16

3.  Subpectoral Biceps Tenodesis Using an All-Suture Anchor.

Authors:  Sarah M Jenkins; Inga M Hwang; Shane Rayos Del Sol; Alvarho J Guzman; Therese Dela Rueda; Patrick McGahan; James Chen
Journal:  Arthrosc Tech       Date:  2022-03-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.