Literature DB >> 14707608

Monitoring right-to-left intracardiac shunt in acute respiratory distress syndrome.

Frédéric Michard, Sami Alaya, Farisa Medkour.   

Abstract

Entities:  

Mesh:

Year:  2004        PMID: 14707608     DOI: 10.1097/01.CCM.0000104921.75069.CD

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


× No keyword cloud information.
  9 in total

1.  Transpulmonary thermodilution curves for detection of shunt.

Authors:  Raphael Giraud; Nils Siegenthaler; Chan Park; Sascha Beutler; Karim Bendjelid
Journal:  Intensive Care Med       Date:  2010-04-16       Impact factor: 17.440

Review 2.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

3.  [Anesthesia in the univentricular heart. Between scylla and charybdis].

Authors:  A R Heller; M Ragaller; R J Litz
Journal:  Anaesthesist       Date:  2005-07       Impact factor: 1.041

4.  The "cross-talk phenomenon" in transpulmonary thermodilution is flow dependent.

Authors:  Joris Lemson; Ruud J R Eijk; Johannes G van der Hoeven
Journal:  Intensive Care Med       Date:  2006-05-09       Impact factor: 17.440

Review 5.  The transpulmonary thermodilution technique.

Authors:  Samir G Sakka; Daniel A Reuter; Azriel Perel
Journal:  J Clin Monit Comput       Date:  2012-07-18       Impact factor: 2.502

6.  Feasibility and Accuracy of Cardiac Right-to-Left-Shunt Detection in Children by New Transpulmonary Ultrasound Dilution Method.

Authors:  Martin Boehne; Mathias Baustert; Verena Paetzel; Dietmar Boethig; Harald Köditz; Nils Dennhardt; Philipp Beerbaum; Harald Bertram
Journal:  Pediatr Cardiol       Date:  2016-11-08       Impact factor: 1.655

Review 7.  [Hemodynamic monitoring in pediatric anesthesia].

Authors:  Andreas Otte; Ehrenfried Schindler; Claudia Neumann
Journal:  Anaesthesiologie       Date:  2022-05-23

8.  Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method.

Authors:  Patrick Kellner; Viola Schleusener; Frank Bauerfeind; Jens Soukup
Journal:  J Clin Monit Comput       Date:  2015-09-04       Impact factor: 2.502

9.  Reliability, repeatability, and reproducibility of pulmonary transit time assessment by contrast enhanced echocardiography.

Authors:  Ingeborg H F Herold; Salvatore Saporito; R Arthur Bouwman; Patrick Houthuizen; Hans C van Assen; Massimo Mischi; Hendrikus H M Korsten
Journal:  Cardiovasc Ultrasound       Date:  2016-01-05       Impact factor: 2.062

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.