Literature DB >> 1470320

Pull-out strength of Caspar cervical screws.

D J Maiman1, F A Pintar, N Yoganandan, J Reinartz, R Toselli, E Woodward, R Haid.   

Abstract

Anterior cervical instrumentation as an adjunct to bone fusion has an important role in cervical spine surgery. Posterior vertebral body cortex purchase is strongly recommended in the use of the Caspar system, although few biomechanical data exist to validate this requirement. In this study, Caspar screws were placed in 43 human cadaveric cervical vertebral bodies, either putting them into the posterior vertebral cortex as identified radiographically or penetrating it by 2 mm as recommended in the literature. Pull-out tests were conducted with tension applied to a connected plate at 0.25 mm/s, and force-deformation data were obtained. Failure typically occurred with clean pull-out; in most instances, cancellous bone remained attached to screw threads. Mean load without posterior cortical purchase was 375 +/- 53 N; with penetration it was 411 +/- 70 N. These differences were nonsignificant. Average deformation to failure was 1.41 +/- 0.10 mm in the group without posterior cortical penetration. In the posterior penetration group, mean deformation was 1.56 +/- 0.16 mm. Again, differences were not significant. Posterior cortical penetration does not improve the pull-out strength of Caspar screws in an isolated vertebral body model, but other biomechanical studies need to be done before insertion methods are altered.

Entities:  

Mesh:

Year:  1992        PMID: 1470320     DOI: 10.1227/00006123-199212000-00016

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  5 in total

1.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

2.  Biomechanical evaluation of subcortical versus bicortical screw purchase in anterior cervical plating.

Authors:  I H Chen
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

Review 3.  Anterior decompressive microsurgery and osteosynthesis for the treatment of multi-segmental cervical spondylosis. Pathophysiological considerations, surgical indication, results and complications: a survey.

Authors:  V Seifert
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

Review 4.  4- and 5-level anterior fusions of the cervical spine: review of literature and clinical results.

Authors:  Heiko Koller; Axel Hempfing; Luis Ferraris; Oliver Maier; Wolfgang Hitzl; Peter Metz-Stavenhagen
Journal:  Eur Spine J       Date:  2007-06-29       Impact factor: 3.134

5.  Operative techniques for cervical radiculopathy and myelopathy.

Authors:  C Moran; C Bolger
Journal:  Adv Orthop       Date:  2011-12-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.