Literature DB >> 14691774

Critical analysis of distal protection devices.

Takao Ohki1, Frank J Veith.   

Abstract

There is considerable evidence that embolization takes place universally during all carotid stenting procedures. In addition, the development of sophisticated distal protection devices and their availability made the concept of cerebral protection widely acceptable, and currently there is a consensus among specialists that protection devices need to be used routinely. The results of the SAFER trial as well as the SAPPHIRE trial have further increased the enthusiasm for routine use of protection devices. However, each additional step to an existing procedure adds potential risks to the procedure. This is true for cerebral protection devices. The problems associated with the use of a distal protection device relate to (1) difficulties in introducing and deploying the device, (2) effectiveness of emboli capture, (3) protection device induced vessel injury, and (4) difficulties in retrieving the device. This article reviews the early clinical experience with various protection devices and summarizes some of the disadvantages of these devices.

Mesh:

Year:  2003        PMID: 14691774     DOI: 10.1053/j.semvascsurg.2003.08.010

Source DB:  PubMed          Journal:  Semin Vasc Surg        ISSN: 0895-7967            Impact factor:   1.000


  10 in total

Review 1.  [Distal protection devices in carotid stent].

Authors:  J Berkefeld; R du Mesnil de Rochemont; M Sitzer; F E Zanella
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

2.  A potential pitfall in the use of the monorail system for carotid stenting. A technical case report.

Authors:  E Pereira; L Birnbaum
Journal:  Interv Neuroradiol       Date:  2007-01-19       Impact factor: 1.610

3.  Diffusion-weighted MR imaging lesions after filter-protected stenting of high-grade symptomatic carotid artery stenoses.

Authors:  R du Mesnil de Rochemont; S Schneider; B Yan; A Lehr; M Sitzer; J Berkefeld
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

Review 4.  Management of extracranial carotid artery disease.

Authors:  Yinn Cher Ooi; Nestor R Gonzalez
Journal:  Cardiol Clin       Date:  2015-02       Impact factor: 2.213

5.  Simulation Study of Distal Balloon Protection Systems during Carotid Artery Stenting.

Authors:  T Kuroiwa; N Sakai; M Sakaguchi; H Adachi; H Imamura; C Sakai; A Morizane; H Ishihara; T Yano; S Nakao; H Kikuchi
Journal:  Interv Neuroradiol       Date:  2008-05-15       Impact factor: 1.610

6.  Symptomatic carotid vasospasm caused by a distal-protection device during stent angioplasty of the right internal carotid artery.

Authors:  Rajesh Vijayvergiya; Parminder S Otaal; Shiv Bagga; Manish Modi
Journal:  Tex Heart Inst J       Date:  2010

7.  Hematological biomarkers for predicting carotid artery vasospasm during carotid stenting.

Authors:  Yusuf Can; Ibrahim Kocayigit
Journal:  Arch Med Sci Atheroscler Dis       Date:  2020-07-27

8.  Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

Authors:  Silke Hopf-Jensen; Leonardo Marques; Michael Preiß; Stefan Müller-Hülsbeck
Journal:  Int J Angiol       Date:  2014-12

9.  Spasm induced by protection balloon during carotid artery stenting.

Authors:  Masanori Tsutsumi; Kiyoshi Kazekawa; Masanari Onizuka; Hiroshi Aikawa; Kouhei Nii; Tomonobu Kodama; Minoru Iko; Makoto Tomokiyo; Shuko Matsubara; Akira Tanaka
Journal:  Radiat Med       Date:  2007-08-27

10.  Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes.

Authors:  Ersan Tatli; Ali Buturak; Yasemin Grunduz; Emir Dogan; Mustafa Alkan; Murat Sayin; Mustafa Yilmaztepe; Selcuk Atakay
Journal:  Postepy Kardiol Interwencyjnej       Date:  2013-09-16       Impact factor: 1.426

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.