Literature DB >> 14688051

Release of gentamicin and vancomycin from temporary human hip spacers in two-stage revision of infected arthroplasty.

E Bertazzoni Minelli1, A Benini, B Magnan, P Bartolozzi.   

Abstract

AIM: Evaluation of the delivery of gentamicin and vancomycin from polymethylmethacrylate (PMMA) spacers before and after implantation for the treatment of total hip replacement infections.
METHODS: Twenty industrially produced spacers containing gentamicin (1.9%) were utilized. Vancomycin (2.5%) mixed with PMMA cement was used to fill holes drilled in the cement of 14 of the 20 spacers immediately before implantation. The spacers were removed from 20 patients 3-6 months after implantation and then immersed in phosphate buffer at 37 degrees C for 10 days. Antibiotic concentrations were determined by fluorescence polarization immunoassay.
RESULTS: Gentamicin and vancomycin were still present in all the spacers removed from the patients. The release of gentamicin alone and in combination with vancomycin was in the range 0.05%-0.4% of the initial amount present, whereas the release of vancomycin was in the range 0.8%-3.3%. The release kinetics showed a similar pattern for both drugs. After a high initial release of drug, a reduced, but constant, elution was observed over the next few days.
CONCLUSIONS: The delivery of gentamicin and vancomycin from PMMA cement was high initially, with sustained release over several months. Incorporation of vancomycin into the surface of the spacers permitted spacers to be prepared with multiple antibiotics present and without adversely affecting the release kinetics of the agents. The gentamicin-vancomycin combination shows potential for the treatment of infection following total hip replacement in specific patients.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14688051     DOI: 10.1093/jac/dkh032

Source DB:  PubMed          Journal:  J Antimicrob Chemother        ISSN: 0305-7453            Impact factor:   5.790


  46 in total

1.  High rate of infection control with one-stage revision of septic knee prostheses excluding MRSA and MRSE.

Authors:  Joachim Singer; Andreas Merz; Lars Frommelt; Bernd Fink
Journal:  Clin Orthop Relat Res       Date:  2011-11-12       Impact factor: 4.176

Review 2.  Infection in total hip replacement: meta-analysis.

Authors:  Surendra Senthi; Jacob T Munro; Rocco P Pitto
Journal:  Int Orthop       Date:  2010-11-18       Impact factor: 3.075

3.  In vivo and in vitro studies of antibiotic release from and bacterial growth inhibition by antibiotic-impregnated polymethylmethacrylate hip spacers.

Authors:  Jens Kelm; Thilo Regitz; Eduard Schmitt; Werner Jung; Konstantinos Anagnostakos
Journal:  Antimicrob Agents Chemother       Date:  2006-01       Impact factor: 5.191

4.  Incorporation of chitosan in acrylic bone cement: effect on antibiotic release, bacterial biofilm formation and mechanical properties.

Authors:  M M Tunney; A J Brady; F Buchanan; C Newe; N J Dunne
Journal:  J Mater Sci Mater Med       Date:  2008-02-12       Impact factor: 3.896

5.  Antimicrobial Release From Prefabricated Spacers Is Variable and the Dose Is Low.

Authors:  Oren Goltzer; Alex McLaren; Derek Overstreet; Christopher Galli; Ryan McLemore
Journal:  Clin Orthop Relat Res       Date:  2015-07       Impact factor: 4.176

6.  Two-stage treatment of infected total knee arthroplasty: two to thirteen year experience using an articulating preformed spacer.

Authors:  Claudio Carlo Castelli; Valerio Gotti; Roberto Ferrari
Journal:  Int Orthop       Date:  2014-01-26       Impact factor: 3.075

Review 7.  Two-stage procedure in the treatment of late chronic hip infections--spacer implantation.

Authors:  Mohamed Sukeik; Fares S Haddad
Journal:  Int J Med Sci       Date:  2009-09-02       Impact factor: 3.738

Review 8.  Revision of late periprosthetic infections of total hip endoprostheses: pros and cons of different concepts.

Authors:  Bernd Fink
Journal:  Int J Med Sci       Date:  2009-09-04       Impact factor: 3.738

Review 9.  Rationale for one stage exchange of infected hip replacement using uncemented implants and antibiotic impregnated bone graft.

Authors:  Heinz Winkler
Journal:  Int J Med Sci       Date:  2009-09-04       Impact factor: 3.738

10.  Elution of gentamicin and vancomycin from polymethylmethacrylate beads and hip spacers in vivo.

Authors:  Konstantinos Anagnostakos; Philippe Wilmes; Eduard Schmitt; Jens Kelm
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more