Literature DB >> 14677194

The compliance-questionnaire-rheumatology compared with electronic medication event monitoring: a validation study.

Erik de Klerk1, Désirée van der Heijde, Robert Landewé, Hille van der Tempel, Sjef van der Linden.   

Abstract

OBJECTIVE: To validate the 19-item Compliance-Questionnaire-Rheumatology (CQR) against the "gold standard" in compliance measurement, electronic medication event monitoring.
METHODS: Among 127 consenting patients, 81 with rheumatoid arthritis taking nonsteroidal antiinflammatory drugs (13 diclofenac, 20 naproxen) or disease modifying antirheumatic drugs (25 sulfasalazine, 23 methotrexate), 17 patients with polymyalgia rheumatica taking prednisone, and 29 patients with gout taking daily prophylactic colchicine (n = 12) or the uric acid lowering drugs allopurinol (10) or benzbromaron (7), 104 used their medication from a regular medication bottle fitted with a special cap containing microelectronics capable of recording time and date of opening and closing, defined as a medication event. Data were processed for the following: (1) the percentage of prescribed medication events during the study period (taking compliance) and (2) the percentage of days with the prescribed number of medication events (i.e., correct dosing). Satisfactory compliance was defined as taking compliance or correct dosing > 80%, while unsatisfactory compliance was defined as taking compliance or correct dosing < or = 80%. All patients were informed about the monitoring, and were followed for 6 months (gout: 1 year). At baseline 85 patients completed a set of questionnaires including the 19-item CQR.
RESULTS: A total of 85 patients who had complete questionnaire and electronic monitoring data were analyzed. Multiple linear regression analyses showed that the total, weighted CQR score significantly and adequately predicts taking compliance (p = 0.001, r2 = 0.46) and correct dosing (p = 0.004, r2 = 0.42). Discriminant analyses showed that specificity and sensitivity to detect good taking compliance were 95% and 62%, respectively, with a prevalence of good compliance of 52%. The predictive value to detect unsatisfactory taking compliance was 86%, and to detect good taking compliance was 83%. The likelihood ratio of the CQR-19 to detect low taking compliance was 11.6. Four items were especially predictive: fear of forgetting to take the drug, being able to function well, routines in daily life, and side effects (combined r2 = 0.35).
CONCLUSION: These results support the validity of the Compliance Questionnaire Rheumatology.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14677194

Source DB:  PubMed          Journal:  J Rheumatol        ISSN: 0315-162X            Impact factor:   4.666


  63 in total

1.  Lancet: a high precision medication event extraction system for clinical text.

Authors:  Zuofeng Li; Feifan Liu; Lamont Antieau; Yonggang Cao; Hong Yu
Journal:  J Am Med Inform Assoc       Date:  2010 Sep-Oct       Impact factor: 4.497

2.  Microprocessor controlled compliance monitor for eye drop medication.

Authors:  M M Hermann; M Diestelhorst
Journal:  Br J Ophthalmol       Date:  2006-03-15       Impact factor: 4.638

3.  Evaluation of treatment adherence in patients with Behçet's disease: its relation to disease manifestations, patients' beliefs about medications, and quality of life.

Authors:  Hania S Zayed; Basma M Medhat; Esraa M Seif
Journal:  Clin Rheumatol       Date:  2018-10-26       Impact factor: 2.980

Review 4.  What are validated self-report adherence scales really measuring?: a systematic review.

Authors:  Thi-My-Uyen Nguyen; Adam La Caze; Neil Cottrell
Journal:  Br J Clin Pharmacol       Date:  2014-03       Impact factor: 4.335

5.  Compliance with treatment of rheumatoid arthritis.

Authors:  Raili Müller; Riina Kallikorm; Kaja Põlluste; Margus Lember
Journal:  Rheumatol Int       Date:  2011-09-24       Impact factor: 2.631

6.  Compliance and knowledge about glaucoma in patients at tertiary glaucoma units.

Authors:  Kaweh Mansouri; Milko E Iliev; Kaspar Rohrer; Tarek Shaarawy
Journal:  Int Ophthalmol       Date:  2011-10-07       Impact factor: 2.031

Review 7.  A scoping review of studies comparing the medication event monitoring system (MEMS) with alternative methods for measuring medication adherence.

Authors:  Mohamed El Alili; Bernard Vrijens; Jenny Demonceau; Silvia M Evers; Mickael Hiligsmann
Journal:  Br J Clin Pharmacol       Date:  2016-05-02       Impact factor: 4.335

8.  Identification of patients at risk of non-adherence to oral antirheumatic drugs in rheumatoid arthritis using the Compliance Questionnaire in Rheumatology: an ARCO sub-study.

Authors:  Carlos Marras; Indalecio Monteagudo; Georgina Salvador; Francisco J de Toro; Alejandro Escudero; Juan J Alegre-Sancho; Enrique Raya; Ana Ortiz; Loreto Carmona; Yvonne Mestre; Luis Cea-Calvo; Jaime Calvo-Alén
Journal:  Rheumatol Int       Date:  2017-05-17       Impact factor: 2.631

9.  Rate and causes of noncompliance with disease-modifying antirheumatic drug regimens in patients with rheumatoid arthritis.

Authors:  Wanruchada Katchamart; Pongthorn Narongroeknawin; Ngamsiree Sukprasert; Wanwisa Chanapai; Ananya Srisomnuek
Journal:  Clin Rheumatol       Date:  2020-09-21       Impact factor: 2.980

10.  Medication persistence over 2 years of follow-up in a cohort of early rheumatoid arthritis patients: associated factors and relationship with disease activity and with disability.

Authors:  Virginia Pascual-Ramos; Irazú Contreras-Yáñez; Antonio R Villa; Javier Cabiedes; Marina Rull-Gabayet
Journal:  Arthritis Res Ther       Date:  2009-02-19       Impact factor: 5.156

View more