| Literature DB >> 14676701 |
Akihiro Ichinose1, Hiroto Terashi, Minoru Nakahara, Isao Sugimoto, Kazunobu Hashikawa, Tadashi Nomura, Nobutaka Ogata, Satoshi Yokoo, Shinya Tahara.
Abstract
Whether or not multiple venous anastomoses reduce the risk of free-flap failure is a subject of controversy. We report here, for the first time, on the importance of selecting 2 separate venous systems of the flap for dual anastomoses. The efficacy of multiple anastomoses was verified through a retrospective review of 310 cases of the free radial forearm flap transfer. Dual anastomoses of separate venous systems (the superficial and the deep) showed a lower incidence of venous insufficiency than single anastomosis did (0.7% versus 7.5%; P < 0.05). On the other hand, dual anastomoses of a sole venous system showed no significant difference in the incidence of venous insufficiency compared with single anastomosis (11.5% versus 7.5%; P = 0.48). Our results suggest that dual venous anastomoses of separate venous systems is conducive to reduced risk of flap failure and affords protection against venous catastrophe through a self-compensating mechanism that obviates thrombosis of either anastomosis.Entities:
Mesh:
Year: 2004 PMID: 14676701 DOI: 10.1097/01.sap.0000096425.18223.60
Source DB: PubMed Journal: Ann Plast Surg ISSN: 0148-7043 Impact factor: 1.539