OBJECTIVE: To compare M mode derived indices of left ventricular performance obtained with transthoracic and transoesophageal echocardiography in children with congenital heart disease.
DESIGN: Transthoracic and transoesophageal M mode echocardiograms were obtained under general anaesthesia before cardiac catheterisation. Recordings were digitised by dedicated software. Indices of cavity dimension and left ventricular wall dynamics were compared. PATIENTS: 16 unselected patients with congenital heart disease.
RESULTS: Group data for simple measurements of ventricular dimension and wall thickness were similar with the two techniques and had acceptable coefficients of repeatability, but there were considerable individual differences. Correlation was poor with unacceptable repeatability for derived indices of cavity and ventricular wall dynamics.
CONCLUSION: Both transthoracic and transoesophageal echocardiography can be used to obtain M mode derived indices of left ventricular performance but the resultant measurements are not directly comparable, presumably because of regional non-uniformity of function.

Entities:  

Mesh:

Year:  1992        PMID: 1467034      PMCID: PMC1025193          DOI: 10.1136/hrt.68.11.485

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  6 in total

1.  Characterisation of the normal right ventricular pressure-volume relation by biplane angiography and simultaneous micromanometer pressure measurements.

Authors:  A N Redington; H H Gray; M E Hodson; M L Rigby; P J Oldershaw
Journal:  Br Heart J       Date:  1988-01

2.  Measurement of instantaneous left ventricular dimension and filling rate in man, using echocardiography.

Authors:  D G Gibson; D Brown
Journal:  Br Heart J       Date:  1973-11

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Application of transesophageal echocardiography to continuous intraoperative monitoring of left ventricular performance.

Authors:  M Matsumoto; Y Oka; J Strom; W Frishman; A Kadish; R M Becker; R W Frater; E H Sonnenblick
Journal:  Am J Cardiol       Date:  1980-07       Impact factor: 2.778

5.  Validation of quantitative intraoperative transesophageal echocardiography.

Authors:  S N Konstadt; D Thys; B P Mindich; J A Kaplan; M Goldman
Journal:  Anesthesiology       Date:  1986-10       Impact factor: 7.892

6.  Angiographic demonstration of incoordinate motion of the ventricular wall after the Fontan operation.

Authors:  D J Penny; A N Redington
Journal:  Br Heart J       Date:  1991-12
  6 in total
  1 in total

1.  Effect of increased wall thickness on indices of left ventricular pump function in children.

Authors:  A Wessel; W C Schüller; T M Yelbuz; J H Bürsch
Journal:  Br Heart J       Date:  1994-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.