Literature DB >> 14670059

Tilted brownian ratchet for DNA analysis.

Lotien Richard Huang1, Edward C Cox, Robert H Austin, James C Sturm.   

Abstract

In this paper, we report a factor of 3 improvement in the resolution and a factor of 10 improvement in the speed of fractionation of approximately 100-kb DNA molecules in Brownian ratchet arrays. In our device, the electrophoretic flow is tilted at a small angle relative to the array axis. Tilting accelerates the fractionation speed because a higher fraction of the diffusing molecules is "ratcheted" at each step in the array. Molecules of lengths 48.5 and 164 kb can be separated in approximately 70 min with a resolution of approximately 3.8, using a 12-mm-long array. The Brownian ratchet arrays are not limited to DNA separation, but can, in principle, be used for any particle in this size range.

Mesh:

Substances:

Year:  2003        PMID: 14670059     DOI: 10.1021/ac0348524

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

Review 1.  Artificial Molecular Machines.

Authors:  Sundus Erbas-Cakmak; David A Leigh; Charlie T McTernan; Alina L Nussbaumer
Journal:  Chem Rev       Date:  2015-09-08       Impact factor: 60.622

Review 2.  Molecular sieving using nanofilters: past, present and future.

Authors:  Jongyoon Han; Jianping Fu; Reto B Schoch
Journal:  Lab Chip       Date:  2007-11-26       Impact factor: 6.799

3.  Tilted post arrays for separating long DNA.

Authors:  Joel D P Thomas; Kevin D Dorfman
Journal:  Biomicrofluidics       Date:  2014-06-16       Impact factor: 2.800

Review 4.  Beyond gel electrophoresis: microfluidic separations, fluorescence burst analysis, and DNA stretching.

Authors:  Kevin D Dorfman; Scott B King; Daniel W Olson; Joel D P Thomas; Douglas R Tree
Journal:  Chem Rev       Date:  2012-11-12       Impact factor: 60.622

5.  Nanofluidic preconcentration and detection of nanoparticles.

Authors:  Anirban Mitra; Filipp Ignatovich; Lukas Novotny
Journal:  J Appl Phys       Date:  2012-07-02       Impact factor: 2.546

6.  Relationship between frequency and deflection angle in the DNA prism.

Authors:  Zhen Chen; Kevin D Dorfman
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2013-01-28

7.  Immunoglobulin G and bovine serum albumin streaming dielectrophoresis in a microfluidic device.

Authors:  Asuka Nakano; Tzu-Chiao Chao; Fernanda Camacho-Alanis; Alexandra Ros
Journal:  Electrophoresis       Date:  2011-07-27       Impact factor: 3.535

Review 8.  Analysis of single nucleic acid molecules in micro- and nano-fluidics.

Authors:  Sarah M Friedrich; Helena C Zec; Tza-Huei Wang
Journal:  Lab Chip       Date:  2016-03-07       Impact factor: 6.799

9.  Pulsed-field separation of particles in a microfluidic device.

Authors:  J Regtmeier; R Eichhorn; T T Duong; P Reimann; D Anselmetti; A Ros
Journal:  Eur Phys J E Soft Matter       Date:  2007-05-11       Impact factor: 1.624

10.  Deterministic Lateral Displacement Microfluidic Chip for Minicell Purification.

Authors:  Ahmad Sherbaz; Büşra M K Konak; Pegah Pezeshkpour; Barbara Di Ventura; Bastian E Rapp
Journal:  Micromachines (Basel)       Date:  2022-02-25       Impact factor: 2.891

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.