Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents.

Stefano Lazzer1, Yves Boirie, Martine Meyer, Michel Vermorel.   

Abstract

The objective of the present study was to determine the accuracy of two foot-to-foot (FF) bioelectrical impedance analysers (BIA) to assess body composition in overweight and obese adolescents, compared with dual-energy X-ray absorptiometry (DXA) and hand-to-foot (HF) BIA. Body composition was assessed in fifty-three overweight or obese adolescents (BMI 27.9 (SD 4.1) kg/m2; aged 13-16 years) by DXA (Hologic QDR-4500; Hologic Inc., Bedford, MA, USA) and BIA (HF (BIA 101, RJL System, Detroit, IL, USA) and FF (Body Fat Monitor Scale BF-625, Tanita Corporation of America Inc., Arlington Heights, IL, USA; Téfal Bodymaster Vision, Téfal, Rumilly, France)). Bland-Altman tests showed that, compared with DXA, FF-Tanita and FF-Téfal underestimated (P<0.05) fat mass (FM) less than HF-BIA (-1.7 (SD 3.1), -0.7 (SD 5.8) and -2.3 (SD 2.2) kg respectively, P<0.001). However, the limits of agreement between DXA and FF-Tanita or FF-Téfal were much greater than those obtained with HF-BIA (-7.7 and +4.3, - 12.0 and +10.6 v. -2.1 and +6.7 kg respectively). The differences between FM assessed using the FF-Tanita or the FF-Téfal analyser and DXA increased with the waist:hip ratio, and were higher in boys than in girls. The major limiting factor of FF-BIA was the inter-individual variability in FM estimates. In conclusion, FF-BIA and DXA are not interchangeable methods. FF-BIA could be acceptable to assess body composition in large groups of overweight or obese adolescents, but cannot be recommended for body composition assessment in obese subjects because of the large errors in individual estimates.

Entities:  

Mesh:

Year:  2003        PMID: 14667192     DOI: 10.1079/bjn2003983

Source DB:  PubMed          Journal:  Br J Nutr        ISSN: 0007-1145            Impact factor:   3.718


  18 in total

Review 1.  The effects of exercise training on fat-mass loss in obese patients during energy intake restriction.

Authors:  Dominique Hansen; Paul Dendale; Jan Berger; Luc J C van Loon; Romain Meeusen
Journal:  Sports Med       Date:  2007       Impact factor: 11.136

Review 2.  Body composition during growth in children: limitations and perspectives of bioelectrical impedance analysis.

Authors:  U G Kyle; C P Earthman; C Pichard; J A Coss-Bu
Journal:  Eur J Clin Nutr       Date:  2015-06-03       Impact factor: 4.016

3.  Evaluation of a new impedancemeter to independently measure extracellular, intracellular and total body water volumes: application to the measurement of hydration.

Authors:  M-V Moreno; E Ribbe-Cornet; J Rebeyrol; A Vannicatte; L Krief
Journal:  Med Biol Eng Comput       Date:  2015-06-03       Impact factor: 2.602

4.  Validity of foot-to-foot bio-electrical impedance analysis body composition estimates in overweight and obese children.

Authors:  D Radley; C B Cooke; N J Fuller; B Oldroyd; J G Truscott; W A Coward; A Wright; P J Gately
Journal:  Int J Body Compos Res       Date:  2009-02

5.  Comparing measures of fat-free mass in overweight older adults using three different bioelectrical impedance devices and three prediction equations.

Authors:  R Ramsey; E Isenring; L Daniels
Journal:  J Nutr Health Aging       Date:  2012-01       Impact factor: 4.075

6.  Bioelectrical impedance and dual-energy x-ray absorptiometry assessments of changes in body composition following exercise in patients with type 2 diabetes mellitus.

Authors:  Masae Miyatani; Pearl Yang; Scott Thomas; B Catharine Craven; Paul Oh
Journal:  J Obes       Date:  2012-09-16

7.  Validity of Four Commercial Bioelectrical Impedance Scales in Measuring Body Fat among Chinese Children and Adolescents.

Authors:  Lin Wang; Stanley Sai-Chuen Hui
Journal:  Biomed Res Int       Date:  2015-06-08       Impact factor: 3.411

8.  Predicting body composition using foot-to-foot bioelectrical impedance analysis in healthy Asian individuals.

Authors:  Chun-Shien Wu; Yu-Yawn Chen; Chih-Lin Chuang; Li-Ming Chiang; Gregory B Dwyer; Ying-Lin Hsu; Ai-Chun Huang; Chung-Liang Lai; Kuen-Chang Hsieh
Journal:  Nutr J       Date:  2015-05-19       Impact factor: 3.271

9.  Percentage of body fat assessment using bioelectrical impedance analysis and dual-energy X-ray absorptiometry in a weight loss program for obese or overweight Chinese adults.

Authors:  Yi-Chun Li; Chia-Ing Li; Wen-Yuan Lin; Chiu-Shong Liu; Hua-Shui Hsu; Cheng-Chun Lee; Fei-Na Chen; Tsai-Chung Li; Cheng-Chieh Lin
Journal:  PLoS One       Date:  2013-04-01       Impact factor: 3.240

10.  Diagnostic accuracy of different body weight and height-based definitions of childhood obesity in identifying overfat among Chinese children and adolescents: a cross-sectional study.

Authors:  Lin Wang; Stanley Sai-chuen Hui
Journal:  BMC Public Health       Date:  2015-08-20       Impact factor: 3.295