Literature DB >> 14655937

Basic dosimetry of radiosurgery narrow beams using Monte Carlo simulations: a detailed study of depth of maximum dose.

A Chaves1, M C Lopes, C C Alves, C Oliveira, L Peralta, P Rodrigues, A Trindade.   

Abstract

In radiosurgery narrow photon beams, the depth of maximum dose d(max), in the beam central axis increases as the size of the additional collimator increases. This behavior is the opposite of what is observed in radiotherapy conventional beams. To understand this effect, experimental depth dose curves of the additional collimators were obtained for a Siemens KD2 linear accelerator in 6 MV photon mode and the shift of d(max) varied from 11.0 +/- 0.6 mm for the 5 mm collimator to 14.5 +/- 0.6 mm for the 23 mm collimator. Monte Carlo simulations showed that the photons that had no interactions in the additional collimators, contributing more than 90% to the total dose in water, were responsible for the shift in d(max). Monte Carlo simulations also showed that electrons originated from these photons and contributing to the dose deposit in water in the beam central axis could be divided in two groups: those that deposit energy far away from their point of origin (the point of the first photon collision in water) and those that deposit energy locally (originated at more than one photon collision in water). Applying a simplified model based on the fact that the photons originating Compton electrons (at the first and subsequent collisions) have similar characteristics in air for all the additional collimators, it was shown that these electrons were also responsible for the shift of d(max) in the beam central axis. Finally, it was shown that the changes in the initial gradients of the depth dose curves of the additional collimators were mainly due to electrons originated from the first photon collision in water.

Entities:  

Mesh:

Year:  2003        PMID: 14655937     DOI: 10.1118/1.1618031

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Multiple-source models for electron beams of a medical linear accelerator using BEAMDP computer code.

Authors:  Nasrollah Jabbari; Amir Hoshang Barati; Leili Rahmatnezhad
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-30

2.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

3.  Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential.

Authors:  F Avraham Dilmanian; Zhong Zhong; Tigran Bacarian; Helene Benveniste; Pantaleo Romanelli; Ruiliang Wang; Jeremy Welwart; Tetsuya Yuasa; Eliot M Rosen; David J Anschel
Journal:  Proc Natl Acad Sci U S A       Date:  2006-06-07       Impact factor: 11.205

  3 in total