Literature DB >> 1464725

Clinical experience with technetium-99m teboroxime scintigraphy in patients referred for myocardial perfusion evaluation.

R Itti1, L Bontemps, Y Sayegh, O Delmas, X Geronicola, X Andre-Fouët.   

Abstract

A series of 30 patients (25 males, 5 females, age = 28-73 years) with a clinical indication of thallium-201 stress/4 hours redistribution scintigraphy has been studied using stress/rest (n = 7) or rest/stress (n = 23) protocols with technetium-99m teboroxime (CARDIOTEC, Squibb Diagnostics) in order to assess the clinical usefulness of this new molecule and to compare it to thallium. In all cases coronary artery disease was known or highly suspected, with a history of myocardial infarction in 18 cases (subacute n = 6, remote n = 12) and/or previous by-pass surgery or PTCA in 5 cases. Medical treatment was not discontinued at the time of stress testing. Coronary angiography was available for 27 patients. Exercise tests for both tracers were carried out on an ergometric bicycle during the same day and the levels of exercise achieved for the thallium studies were very similar to those achieved for teboroxime. Imaging was performed in three planar projections and sudies were evaluated using a model with 4 territories: septal and anterior assumed to correspond to the LAD artery, lateral and latero-posterior (= LCX), inferior and posterior (= RCA) and apex. Classification of results was: normal, ischemic, infarcted and infarcted with ischemia. With reference to the thallium-201 results, agreement was found in 86% (37/43) of normal regions and in 82% (63/77) of abnormal regions. Relative to documented coronary artery lesions (27 patients) sensitivity and specificity of thallium and teboroxime for exact correspondence between arteries and territories were, respectively: thallium, se = 71%, sp = 64%, teboroxime, se = 67%, sp = 75%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1464725     DOI: 10.1007/bf01146024

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  9 in total

1.  Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile.

Authors:  R D Okada; D Glover; T Gaffney; S Williams
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

2.  Hexakis (2-methoxy isobutylisonitrile) technetium-99m and thallium-201 chloride: uptake and release in cultured myocardial cells.

Authors:  J C Maublant; P Gachon; N Moins
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

3.  Same day injections of Tc-99m methoxy isobutyl isonitrile (hexamibi) for myocardial tomographic imaging: comparison between rest-stress and stress-rest injection sequences.

Authors:  R Taillefer; A Gagnon; L Laflamme; J Grégoire; J Léveillé; D C Phaneuf
Journal:  Eur J Nucl Med       Date:  1989

Review 4.  Clinical experience with technetium-99m teboroxime, a neutral, lipophilic myocardial perfusion imaging agent.

Authors:  L L Johnson; D W Seldin
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

5.  Increased lung uptake of thallium-201 during exercise myocardial imaging: clinical, hemodynamic and angiographic implications in patients with coronary artery disease.

Authors:  C A Boucher; L M Zir; G A Beller; R D Okada; K A McKusick; H W Strauss; G M Pohost
Journal:  Am J Cardiol       Date:  1980-08       Impact factor: 2.778

6.  Myocardial perfusion imaging with technetium-99m SQ30217: comparison with thallium-201 and coronary anatomy.

Authors:  D W Seldin; L L Johnson; D K Blood; M J Muschel; K F Smith; R M Wall; P J Cannon
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

7.  Myocardial perfusion imaging with a new radiotracer, technetium-99m-hexamibi (methoxy isobutyl isonitrile): comparison with thallium-201 imaging.

Authors:  R Taillefer; G Dupras; V Sporn; P Rigo; J Leveille; P Boucher; N Perez-Balino; L L Camin; K A McKusick
Journal:  Clin Nucl Med       Date:  1989-02       Impact factor: 7.794

8.  Cationic Tc-99m complexes as potential myocardial imaging agents.

Authors:  E Deutsch; K A Glavan; V J Sodd; H Nishiyama; D L Ferguson; S J Lukes
Journal:  J Nucl Med       Date:  1981-10       Impact factor: 10.057

9.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.

Authors:  F J Wackers; D S Berman; J Maddahi; D D Watson; G A Beller; H W Strauss; C A Boucher; M Picard; B L Holman; R Fridrich
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

  9 in total