Literature DB >> 14645882

Glomerular filtration rate measured by using triphasic helical CT with a two-point Patlak plot technique.

Nils Hackstein1, Cornelia Wiegand, Wigbert Stefan Rau, Alexander Claus Langheinrich.   

Abstract

PURPOSE: To determine the accuracy of the two-point Patlak plot in the calculation of glomerular filtration rate (GFR).
MATERIALS AND METHODS: Fifty patients without acute renal disorder were included. GFR was calculated by using a two-point Patlak plot technique. The computed tomography (CT) protocol consisted of a plain examination followed by two contrast material-enhanced examinations in the arterial and portovenous phase. Each examination included the entire kidneys and was performed after injection of 120 mL iopromide and 300 mg of iodine per milliliter given per 75 kg of body weight. All examinations were performed with a standard abdominal protocol. Section thickness was 4 x 2.5 mm, and table advance was 12.5 mm. Bolus triggering commenced 10 seconds after the start of contrast medium injection. Twelve dynamic scans were obtained with reduced tube current every 3 seconds to obtain sufficient arterial input function data. Correction for hematocrit level was made by using the unenhanced attenuation of the aorta. As a reference method, plasma clearance of the contrast medium injected for CT was calculated from three iodine plasma concentration measurements obtained 3, 4, and 5 hours after injection. Linear correlation was performed.
RESULTS: GFR was calculated from CT data in 48 patients. Two patients were excluded because of breathing errors. Mean GFR was 80 mL/min (range, 17-153 mL/min) as measured with iopromide plasma clearance and 82 mL/min (range, 28-148 mL/min) as measured with CT. Linear correlation between the two methods was r = 0.889; GFR calculated with the two-point Patlak plot was equal to 15 plus 0.83 times GFR (plasma clearance). The mean difference between GFRs as determined with the two methods was -1.2 mL/min (95% CI: -27.1, 24.6).
CONCLUSION: Total GFR can be measured accurately with minimally extended triphasic CT in patients without acute renal disorder by using a two-point Patlak plot technique. Copyright RSNA, 2004

Entities:  

Mesh:

Year:  2003        PMID: 14645882     DOI: 10.1148/radiol.2301021266

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  10 in total

Review 1.  Quantitative and qualitative analysis and interpretation of CT perfusion imaging.

Authors:  Carolina Valdiviezo; Marietta Ambrose; Vishal Mehra; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

Review 2.  Contemporary imaging modalities for the surveillance of patients with renal cell carcinoma.

Authors:  Matthew K Tollefson; Naoki Takahashi; Bradley C Leibovich
Journal:  Curr Urol Rep       Date:  2007-01       Impact factor: 3.092

3.  Development of a method for automated and stable myocardial perfusion measurement using coronary X-ray angiography images.

Authors:  Takuya Sakaguchi; Takashi Ichihara; Takahiro Natsume; Jingwu Yao; Omair Yousuf; Jeffrey C Trost; Joao A C Lima; Richard T George
Journal:  Int J Cardiovasc Imaging       Date:  2015-04-17       Impact factor: 2.357

4.  Relative Patlak plot for dynamic PET parametric imaging without the need for early-time input function.

Authors:  Yang Zuo; Jinyi Qi; Guobao Wang
Journal:  Phys Med Biol       Date:  2018-08-10       Impact factor: 3.609

5.  Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method.

Authors:  Shan You; XianWu Ma; ChangZhu Zhang; Qiang Li; WenWei Shi; Jing Zhang; XiaoDong Yuan
Journal:  Eur Radiol       Date:  2017-10-02       Impact factor: 5.315

6.  Transgenic overexpression of p23 induces spontaneous hydronephrosis in mice.

Authors:  Jaehoon Lee; Hye Jin Kim; Jung Ah Moon; Young Hoon Sung; In-Jeoung Baek; Jae-il Roh; Na Young Ha; Seung-Yeon Kim; Young Yil Bahk; Jong Eun Lee; Tae Hyun Yoo; Han-Woong Lee
Journal:  Int J Exp Pathol       Date:  2011-02-16       Impact factor: 1.925

Review 7.  Novel imaging techniques in acute kidney injury.

Authors:  Kambiz Kalantarinia
Journal:  Curr Drug Targets       Date:  2009-12       Impact factor: 3.465

Review 8.  Role of imaging in the evaluation of renal dysfunction in heart failure patients.

Authors:  Dario Grande; Paola Terlizzese; Massimo Iacoviello
Journal:  World J Nephrol       Date:  2017-05-06

9.  Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?

Authors:  Hira Lal; Anuradha Singh; Raghunandan Prasad; Priyank Yadav; Javed Akhtar; Sukanta Barai; Prabhakar Mishra; Dharmendra Bhadauria; Anupma Kaul; Narayan Prasad; Pragati Verma
Journal:  SA J Radiol       Date:  2021-03-05

10.  Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and (99m)Tc - DTPA renal scan.

Authors:  Debanga Sarma; Sasanka K Barua; T P Rajeev; Saumar J Baruah
Journal:  Indian J Urol       Date:  2012-10
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.