Literature DB >> 30020080

Relative Patlak plot for dynamic PET parametric imaging without the need for early-time input function.

Yang Zuo1, Jinyi Qi, Guobao Wang.   

Abstract

The Patlak graphical method is widely used in parametric imaging for modeling irreversible radiotracer kinetics in dynamic PET. The net influx rate of radiotracer can be determined from the slope of the Patlak plot. The implementation of the standard Patlak method requires the knowledge of full-time input function from the injection time until the scan end time, which presents a challenge for use in the clinic. This paper proposes a new relative Patlak plot method that does not require early-time input function and therefore can be more efficient for parametric imaging. Theoretical analysis proves that the effect of early-time input function is a constant scaling factor on the Patlak slope estimation. Thus, the parametric image of the slope of the relative Patlak plot is related to the parametric image of standard Patlak slope by a global scaling factor. This theoretical finding has been further demonstrated by computer simulation and real patient data. The study indicates that parametric imaging of the relative Patlak slope can be used as a substitute of parametric imaging of standard Patlak slope for tasks that do not require absolute quantification, such as lesion detection and tumor volume segmentation.

Entities:  

Mesh:

Year:  2018        PMID: 30020080      PMCID: PMC6133657          DOI: 10.1088/1361-6560/aad444

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  29 in total

1.  Measuring single-kidney glomerular filtration rate on single-detector helical CT using a two-point Patlak plot technique in patients with increased interstitial space.

Authors:  Nils Hackstein; Julia Bauer; Ekkehard W Hauck; Martin Ludwig; Hans-Joachim Krämer; Wigbert Stefan Rau
Journal:  AJR Am J Roentgenol       Date:  2003-07       Impact factor: 3.959

2.  Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

Authors:  Jing Tang; Hiroto Kuwabara; Dean F Wong; Arman Rahmim
Journal:  Phys Med Biol       Date:  2010-07-20       Impact factor: 3.609

3.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.

Authors:  Charalampos Tsoumpas; Federico E Turkheimer; Kris Thielemans
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

Review 4.  Four-dimensional (4D) image reconstruction strategies in dynamic PET: beyond conventional independent frame reconstruction.

Authors:  Arman Rahmim; Jing Tang; Habib Zaidi
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

5.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations.

Authors:  C S Patlak; R G Blasberg
Journal:  J Cereb Blood Flow Metab       Date:  1985-12       Impact factor: 6.200

6.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data.

Authors:  C S Patlak; R G Blasberg; J D Fenstermacher
Journal:  J Cereb Blood Flow Metab       Date:  1983-03       Impact factor: 6.200

7.  Lesion detection in dynamic FDG-PET using matched subspace detection.

Authors:  Zheng Li; Quanzheng Li; Xiaoli Yu; Peter S Conti; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2009-02       Impact factor: 10.048

8.  A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET.

Authors:  Y Choi; S C Huang; R A Hawkins; W G Kuhle; M Dahlbom; C K Hoh; J Czernin; M E Phelps; H R Schelbert
Journal:  J Nucl Med       Date:  1993-03       Impact factor: 10.057

9.  Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography.

Authors:  D Feng; S C Huang; X Wang
Journal:  Int J Biomed Comput       Date:  1993-03

10.  Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET.

Authors:  Nicolas A Karakatsanis; Yun Zhou; Martin A Lodge; Michael E Casey; Richard L Wahl; Habib Zaidi; Arman Rahmim
Journal:  Phys Med Biol       Date:  2015-10-28       Impact factor: 3.609

View more
  2 in total

Review 1.  Total-body PET/CT - First Clinical Experiences and Future Perspectives.

Authors:  Quinn Kwan-Tai Ng; Elizabeth Katherine Anna Triumbari; Negar Omidvari; Simon R Cherry; Ramsey D Badawi; Lorenzo Nardo
Journal:  Semin Nucl Med       Date:  2022-03-07       Impact factor: 4.802

2.  Computational modeling of PET tracer distribution in solid tumors integrating microvasculature.

Authors:  Niloofar Fasaeiyan; M Soltani; Farshad Moradi Kashkooli; Erfan Taatizadeh; Arman Rahmim
Journal:  BMC Biotechnol       Date:  2021-11-25       Impact factor: 2.563

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.