A comparison of the International Standards Organisation reference method for the detection of coliforms and Escherichia coli in water with a defined substrate procedure.

S I Niemela1, J V Lee, C R Fricker.   

Abstract

AIMS: This study investigated the use of the International Standards Organisation (ISO) procedure for the comparison of microbiological methods. Using this procedure the ISO reference procedure for the detection of coliforms and Escherichia coli in water was compared with a defined substrate method (ColilertTM). METHODS AND
RESULTS: A total of 20 laboratories from 13 European countries compared the use of Colilert/Quanti-TrayTM, a quantitative defined substrate test (DST) for the presence of coliforms and E. coli with the ISO reference procedure, which utilizes tergitol-TTC medium. Results of the study showed that DST detected significantly more coliforms and E. coli than did the reference procedure. In the case of E. coli the recoveries were also higher when using DST and the difference seen was statistically significant. The confirmation rate obtained when using the DST product suggested that no confirmation of wells positive for E. coli was necessary during routine use.
CONCLUSIONS: Colilert is a suitable alternative to the ISO reference procedure for the detection of coliforms and E. coli in water. The methods used during the comparison study indicated that confirmation of all colonies/positive wells led to the most accurate information and it is recommended that for future comparison studies this should become standard practice. Confirmation of a small proportion of colonies led to misleading conclusions and should be avoided when comparing microbiological methods. SIGNIFICANCE AND IMPACT OF STUDY: It has been demonstrated that the ISO reference procedure fails to detect a significant proportion of coliforms and E. coli in drinking water. Colilert/QuantiTrayTM is a more suitable alternative.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14633003     DOI: 10.1046/j.1365-2672.2003.02099.x

Source DB:  PubMed          Journal:  J Appl Microbiol        ISSN: 1364-5072            Impact factor:   3.772


  4 in total

1.  A comparison of bacterial indicators and methods in rural surface waters.

Authors:  Robin W Kloot; Bobby Radakovich; Xiaoqing Huang; Daniel Duke Brantley
Journal:  Environ Monit Assess       Date:  2006-06-02       Impact factor: 2.513

2.  High prevalence of multiple-antibiotic-resistant (MAR) Escherichia coli in river bed sediments of the Apies River, South Africa.

Authors:  Akebe Luther King Abia; Eunice Ubomba-Jaswa; Maggy Ndombo Benteke Momba
Journal:  Environ Monit Assess       Date:  2015-09-30       Impact factor: 2.513

3.  Microbiological monitoring and automated event sampling at karst springs using LEO-satellites.

Authors:  H Stadler; P Skritek; R Sommer; R L Mach; W Zerobin; A H Farnleitner
Journal:  Water Sci Technol       Date:  2008       Impact factor: 1.915

Review 4.  Bathing Water Quality Monitoring Practices in Europe and the United States.

Authors:  Ananda Tiwari; David M Oliver; Aaron Bivins; Samendra P Sherchan; Tarja Pitkänen
Journal:  Int J Environ Res Public Health       Date:  2021-05-21       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.