Literature DB >> 14623938

Quantitative comparison of long-wavelength Alexa Fluor dyes to Cy dyes: fluorescence of the dyes and their bioconjugates.

Judith E Berlier1, Anca Rothe, Gayle Buller, Jolene Bradford, Diane R Gray, Brian J Filanoski, William G Telford, Stephen Yue, Jixiang Liu, Ching-Ying Cheung, Wesley Chang, James D Hirsch, Joseph M Beechem, Rosaria P Haugland, Richard P Haugland.   

Abstract

Amine-reactive N-hydroxysuccinimidyl esters of Alexa Fluor fluorescent dyes with principal absorption maxima at about 555 nm, 633 nm, 647 nm, 660 nm, 680 nm, 700 nm, and 750 nm were conjugated to antibodies and other selected proteins. These conjugates were compared with spectrally similar protein conjugates of the Cy3, Cy5, Cy5.5, Cy7, DY-630, DY-635, DY-680, and Atto 565 dyes. As N-hydroxysuccinimidyl ester dyes, the Alexa Fluor 555 dye was similar to the Cy3 dye, and the Alexa Fluor 647 dye was similar to the Cy5 dye with respect to absorption maxima, emission maxima, Stokes shifts, and extinction coefficients. However, both Alexa Fluor dyes were significantly more resistant to photobleaching than were their Cy dye counterparts. Absorption spectra of protein conjugates prepared from these dyes showed prominent blue-shifted shoulder peaks for conjugates of the Cy dyes but only minor shoulder peaks for conjugates of the Alexa Fluor dyes. The anomalous peaks, previously observed for protein conjugates of the Cy5 dye, are presumably due to the formation of dye aggregates. Absorption of light by the dye aggregates does not result in fluorescence, thereby diminishing the fluorescence of the conjugates. The Alexa Fluor 555 and the Alexa Fluor 647 dyes in protein conjugates exhibited significantly less of this self-quenching, and therefore the protein conjugates of Alexa Fluor dyes were significantly more fluorescent than those of the Cy dyes, especially at high degrees of labeling. The results from our flow cytometry, immunocytochemistry, and immunohistochemistry experiments demonstrate that protein-conjugated, long-wavelength Alexa Fluor dyes have advantages compared to the Cy dyes and other long-wavelength dyes in typical fluorescence-based cell labeling applications.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14623938     DOI: 10.1177/002215540305101214

Source DB:  PubMed          Journal:  J Histochem Cytochem        ISSN: 0022-1554            Impact factor:   2.479


  78 in total

1.  STED nanoscopy in living cells using Fluorogen Activating Proteins.

Authors:  James A J Fitzpatrick; Qi Yan; Jochen J Sieber; Marcus Dyba; Ulf Schwarz; Chris Szent-Gyorgyi; Carol A Woolford; Peter B Berget; Alan S Waggoner; Marcel P Bruchez
Journal:  Bioconjug Chem       Date:  2009       Impact factor: 4.774

2.  Combining catalyzed reporter deposition-fluorescence in situ hybridization and microautoradiography to detect substrate utilization by bacteria and Archaea in the deep ocean.

Authors:  Eva Teira; Thomas Reinthaler; Annelie Pernthaler; Jakob Pernthaler; Gerhard J Herndl
Journal:  Appl Environ Microbiol       Date:  2004-07       Impact factor: 4.792

3.  Multi-image colocalization and its statistical significance.

Authors:  Patrick A Fletcher; David R L Scriven; Meredith N Schulson; Edwin D W Moore
Journal:  Biophys J       Date:  2010-09-22       Impact factor: 4.033

4.  Improved speciation characteristics of PEGylated indocyanine green-labeled Panitumumab: revisiting the solution and spectroscopic properties of a near-infrared emitting anti-HER1 antibody for optical imaging of cancer.

Authors:  Aaron Joseph L Villaraza; Diane E Milenic; Martin W Brechbiel
Journal:  Bioconjug Chem       Date:  2010-11-12       Impact factor: 4.774

5.  Sterically Shielded Heptamethine Cyanine Dyes for Bioconjugation and High Performance Near-Infrared Fluorescence Imaging.

Authors:  Dong-Hao Li; Cynthia L Schreiber; Bradley D Smith
Journal:  Angew Chem Int Ed Engl       Date:  2020-05-11       Impact factor: 15.336

6.  Design, synthesis, and pharmacological characterization of fluorescent peptides for imaging human V1b vasopressin or oxytocin receptors.

Authors:  Maithé Corbani; Miguel Trueba; Stoytcho Stoev; Brigitte Murat; Julie Mion; Véra Boulay; Gilles Guillon; Maurice Manning
Journal:  J Med Chem       Date:  2011-03-23       Impact factor: 7.446

Review 7.  Histidine-tag-directed chromophores for tracer analyses in the analytical ultracentrifuge.

Authors:  Lance M Hellman; Chunxia Zhao; Manana Melikishvili; Xiaorong Tao; James E Hopper; Sidney W Whiteheart; Michael G Fried
Journal:  Methods       Date:  2010-12-25       Impact factor: 3.608

Review 8.  Bright ideas for chemical biology.

Authors:  Luke D Lavis; Ronald T Raines
Journal:  ACS Chem Biol       Date:  2008-03-20       Impact factor: 5.100

9.  Discovery and early development of squaraine rotaxanes.

Authors:  Jeremiah J Gassensmith; Jeffrey M Baumes; Bradley D Smith
Journal:  Chem Commun (Camb)       Date:  2009-08-24       Impact factor: 6.222

10.  Long lived BSA Au clusters as a time gated intensity imaging probe.

Authors:  S L Raut; R Fudala; R Rich; R A Kokate; R Chib; Z Gryczynski; I Gryczynski
Journal:  Nanoscale       Date:  2014-01-27       Impact factor: 7.790

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.