Literature DB >> 14622313

The influence of high versus normal impedance ventricular leads on pacemaker generator longevity.

Thomas Berger1, Franz X Roithinger, Herwig Antretter, Herbert Hangler, Otmar Pachinger, Florian Hintringer.   

Abstract

As pacemaker generator longevity is dependent on current consumption and resistance of the pacing lead, the use of a high impedance pacing lead theoretically results in an extension of battery longevity. Therefore, the effect of high versus standard impedance ventricular leads on generator longevity was studied. In 40 patients (21 women, age 73 +/- 13 years) with a standard dual chamber pacemaker indication, a bipolar standard impedance ventricular lead was implanted in 20 patients, the remaining patients received a bipolar high impedance lead in a randomized fashion. All patients received identical pacemaker generators and atrial leads. The estimated longevity of the generator was calculated automatically by a programmed pacemaker algorithm. After a mean follow-up of 39 +/- 4.8 months, no significant differences were observed with respect to mean pacing and sensing thresholds of the atrial and ventricular leads in both groups. However, the high impedance leads displayed a significantly higher impedance and a significantly lower current drain as compared to standard impedance leads (1,044 +/- 139 vs 585 +/- 90 Omega, and 2.2 +/- 0.4 vs 4.3 +/- 1.1 mA). The extrapolated generator longevity was significantly longer in the high impedance lead group, as compared to the standard impedance lead group (107.3 +/- 8.5 vs 97.6 +/- 9.0 months; P = 0.02). In conclusion, implantation of a high impedance lead for ventricular pacing results in a clinically relevant extension of generator longevity.

Entities:  

Mesh:

Year:  2003        PMID: 14622313     DOI: 10.1046/j.1460-9592.2003.00329.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Increased hs-CRP and decreased 1,25-dihydroxyvitamin D are associated with increased left ventricle lead threshold.

Authors:  Gökhan Gözübüyük; Mevlüt Koç; Onur Kaypaklı; Durmuş Yıldıray Şahin
Journal:  J Interv Card Electrophysiol       Date:  2016-05-28       Impact factor: 1.900

Review 2.  Leadless Cardiac Pacemakers: Pacing Paradigm Change.

Authors:  Petr Neuzil; Vivek Y Reddy
Journal:  Curr Cardiol Rep       Date:  2015-08       Impact factor: 2.931

3.  Pacemaker longevity: the world's longest-lasting VVI pacemaker.

Authors:  David Katz; Toshio Akiyama
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-07       Impact factor: 1.468

4.  Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system.

Authors:  Parinaz Abiri; Ahmad Abiri; René R Sevag Packard; Yichen Ding; Alireza Yousefi; Jianguo Ma; Malcolm Bersohn; Kim-Lien Nguyen; Dejan Markovic; Shervin Moloudi; Tzung K Hsiai
Journal:  Sci Rep       Date:  2017-07-21       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.