Literature DB >> 14617529

VO2, VCO2, and RQ in a respiratory chamber: accurate estimation based on a new mathematical model using the Kalman-Bucy method.

L Granato1, A Brandes, C Bruni, A V Greco, G Mingrone.   

Abstract

A respiratory chamber is used for monitoring O(2) consumption (Vo(2)), CO(2) production (Vco(2)), and respiratory quotient (RQ) in humans, enabling long term (24-h) observation under free-living conditions. Computation of Vo(2) and Vco(2) is currently done by inversion of a mass balance equation, with no consideration of measurement errors and other uncertainties. To improve the accuracy of the results, a new mathematical model is suggested in the present study explicitly accounting for the presence of such uncertainties and error sources and enabling the use of optimal filtering methods. Experiments have been realized, injecting known gas quantities and estimating them using the proposed mathematical model and the Kalman-Bucy (KB) estimation method. The estimates obtained reproduce the known production rates much better than standard methods; in particular, the mean error when fitting the known production rates is 15.6 +/- 0.9 vs. 186 +/- 36 ml/min obtained using a conventional method. Experiments with 11 humans were carried out as well, where Vo(2) and Vco(2) were estimated. The variance of the estimation errors, produced by the KB method, appears relatively small and rapidly convergent. Spectral analysis is performed to assess the residual noise content in the estimates, revealing large improvement: 2.9 +/- 0.8 vs. 3,440 +/- 824 (ml/min)(2) and 1.8 +/- 0.5 vs. 2,057 +/- 532 (ml/min)(2), respectively, for Vo(2) and Vco(2) estimates. Consequently, the accuracy of the computed RQ is also highly improved (0.3 x 10(-4) vs. 800 x 10(-4)). The presented study demonstrates the validity of the proposed model and the improvement in the results when using a KB estimation method to resolve it.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14617529     DOI: 10.1152/japplphysiol.00788.2003

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  7 in total

1.  Algorithm to improve accuracy of energy expended in a room calorimeter.

Authors:  Haiying Quan; Wenrui Hao; Lu Li; Ming Sun; Kuan Zhang
Journal:  Med Biol Eng Comput       Date:  2016-10-20       Impact factor: 2.602

2.  Genes involved in mitochondrial biogenesis/function are induced in response to bilio-pancreatic diversion in morbidly obese individuals with normal glucose tolerance but not in type 2 diabetic patients.

Authors:  M I Hernández-Alvarez; C Chiellini; M Manco; D Naon; M Liesa; M Palacín; G Mingrone; A Zorzano
Journal:  Diabetologia       Date:  2009-06-06       Impact factor: 10.122

3.  Estimation of Instantaneous Gas Exchange in Flow-Through Respirometry Systems: A Modern Revision of Bartholomew's Z-Transform Method.

Authors:  Hodjat Pendar; John J Socha
Journal:  PLoS One       Date:  2015-10-14       Impact factor: 3.240

4.  Measuring the short-term substrate utilization response to high-carbohydrate and high-fat meals in the whole-body indirect calorimeter.

Authors:  Andrei Gribok; Jayme L Leger; Michelle Stevens; Reed Hoyt; Mark Buller; William Rumpler
Journal:  Physiol Rep       Date:  2016-06

5.  Improving temporal accuracy of human metabolic chambers for dynamic metabolic studies.

Authors:  Shanshan Chen; Erica Wohlers; Eric Ruud; Jon Moon; Bin Ni; Francesco S Celi
Journal:  PLoS One       Date:  2018-04-24       Impact factor: 3.240

6.  Advances in Nutritional Epigenetics-A Fresh Perspective for an Old Idea. Lessons Learned, Limitations, and Future Directions.

Authors:  Lynda Sedley
Journal:  Epigenet Insights       Date:  2020-12-18

7.  Codonopsis lanceolata Water Extract Increases Hepatic Insulin Sensitivity in Rats with Experimentally-Induced Type 2 Diabetes.

Authors:  Seong-Yeop Jeong; Suna Kang; Da Sol Kim; Sunmin Park
Journal:  Nutrients       Date:  2017-11-01       Impact factor: 5.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.