Literature DB >> 14617120

Influence of EEG monitoring on intraoperative stapedius reflex threshold values in cochlear implantation in children.

B Schultz1, F A Beger, B P Weber, O Niclaus, E Lüllwitz, U Grouven, A Schultz.   

Abstract

BACKGROUND: Cochlear implantation is a widely used means of treating deafness and severe hearing disorders. The surgical procedure includes inserting the cochlear implant electrode array into the cochlea and embedding the corresponding signal receiver in the mastoid bone behind the ear. Postoperative fitting of the externally worn speech processor is very important for successful use of the cochlear implant. For this purpose, electrically elicited stapedius reflex threshold values can be used. However, stapedius reflex threshold values measured intraoperatively are influenced by anaesthetics. The goal of this retrospective study was to find out whether electroencephalogram (EEG) control of anaesthesia produces more reliable reflex threshold values as a basis for the fitting of the speech processor.
METHODS: Three groups of children, after surgery for cochlear implantation, were analysed with regard to the magnitude of intraoperative electrically elicited stapedius reflex threshold values and their deviations from postoperatively determined maximum comfortable levels (group 1: methohexital/remifentanil with EEG monitoring, n = 10; group 2: isoflurane/fentanyl with EEG monitoring, n = 9; group 3: isoflurane/fentanyl without EEG monitoring, n = 11).
RESULTS: Children with EEG monitoring had significantly lower electrically elicited stapedius reflex threshold values and also significantly lower differences between intraoperative stapedius reflex threshold values and postoperatively determined maximum comfortable levels.
CONCLUSIONS: Electroencephalogram monitoring in cochlear implantation is of considerable value in controlling anaesthesia and improving speech processor fitting based on more reliable intraoperative neurophysiological data.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14617120     DOI: 10.1046/j.1460-9592.2003.01154.x

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  2 in total

1.  Evaluation of volatile and intravenous anesthetics, effects on the threshold of neuroresponse telemetry and the threshold of acoustically evoked stapedial reflex in children undergoing cochlear implant surgery.

Authors:  Mahin Seyed Hejazi; Yalda Jabbari Moghaddam; Masoud Nader Pour; Mehdi Banaii; Reihane Abri; Nasrin Taghizadieh
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2018 Apr-Jun

2.  Automated detection of electrically evoked stapedius reflexes (eSR) during cochlear implantation.

Authors:  Nora M Weiss; Attila Óvári; Tobias Oberhoffner; Laurent Demaret; Atabek Bicer; Sebastian Schraven; Karsten Ehrt; Rüdiger Dahl; Armin Schneider; Robert Mlynski
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-08-03       Impact factor: 2.503

  2 in total